Tog (unit)
The tog is a measure of thermal resistance of a unit area, also known as thermal insulance. It is commonly used in the textile industry and often seen quoted on, for example, duvets and carpet underlay.
The Shirley Institute in Manchester, England developed the tog as an easy-to-follow alternative to the SI unit of m2K/W.[1] The name comes from the informal word "togs" for clothing which itself was probably derived from the word toga, a Roman garment.
The basic unit of insulation coefficient is the RSI, (1 m2K/W). 1 tog = 0.1 RSI. There is also a clo clothing unit equivalent to 0.155 RSI or 1.55 tog.
A tog is 0.1 m2K/W. In other words, the thermal resistance in togs is equal to ten times the temperature difference (in °C) between the two surfaces of a material, when the flow of heat is equal to one watt per square metre.
British duvets are sold in steps of 1.5 tog from 4.5 tog (summer) to 16.5 tog (extra-warm). The stated values are minimal, actual values may be up to 3 tog higher. Notice that these tog values assume that there is no duvet cover added that can trap air, and that the sleeper is unclothed. Sleepwear and such other layers can make a significant difference for the lower tog values.
Lightweight summer duvet: | 3.0 - 4.5 tog |
Spring/Autumn weight duvet: | 7.5 - 10.5 tog |
Winter weight duvet: | 12.0 - 13.5 tog |
A few manufacturers have marketed combined duvet sets consisting of two duvets; one of approximately 4.5 tog and one of approximately 9.0 tog. These can be used individually as summer (4.5 tog) and spring/autumn (9.0 tog). When joined together using press studs around the edges, or Velcro strips across each of the corners, they become a 13.5 tog winter duvet and as such can be made to suit all seasons.
The tog is also used to define the thermal properties of carpet underlay.
Tog Testing
Launched in the 1940s by The Shirley Institute, the Shirley Togmeter is the standard apparatus for rating thermal resistance of textiles, commonly known as the Tog Test. This apparatus, described in BS 4745, measures a sample of textile, either between two metal plates (for underclothing) or between a metal plate and free air (for outer layers).
Each industry has its own specifications and methods for measuring thermal properties. The Shirley Togmeter is unsuitable for duvets because the large scale of their quilted construction makes it impractical to obtain a representative sample of suitable size. BS5335 describes apparatus for duvet tog testing. This consists of a metal plate at least 1000 mm x 600 mm at skin temperature (33°C) arranged to support the whole duvet, and a mechanism for measuring the air temperature above the quilt. This requires very precise control of the laboratory environment in order to get reliable results.
BS 8510 describes tog testing for baby products, the concern here being to ensure that babies do not overheat.
Measurement of the clo, a similar measure used in the USA, is described in ASTM D-1518.
See also
Notes
If we call the reciprocal of the insulation coefficient, the conductivity G in W/m2K then a handy backronym for remembering what Tog means is "10/G", or "Ten Over G."
References
- ↑ Kennard, Harry (March 7, 2017). "What's a Tog".