Specific speed

Specific speed Ns, is used to characterize turbomachinery speed.[1] Common commercial and industrial practices use dimensioned versions which are of equal utility. Specific speed is most commonly used in pump applications to define the suction specific speed —a quasi non-dimensional number that categorizes pump impellers as to their type and proportions. In Imperial units it is defined as the speed in revolutions per minute at which a geometrically similar impeller would operate if it were of such a size as to deliver one gallon per minute against one foot of hydraulic head. In metric units flow may be in l/s or m³/s and head in m, and care must be taken to state the units used.

Performance is defined as the ratio of the pump or turbine against a reference pump or turbine, which divides the actual performance figure to provide a unitless figure of merit. The resulting figure would more descriptively be called the "ideal-reference-device-specific performance." This resulting unitless ratio may loosely be expressed as a "speed," only because the performance of the reference ideal pump is linearly dependent on its speed, so that the ratio of [device-performance to reference-device-performance] is also the increased speed at which the reference device would need to operate, in order to produce the performance, instead of its reference speed of "1 unit."

Specific speed is an index used to predict desired pump or turbine performance. i.e. it predicts the general shape of a pumps impeller. It is this impeller's "shape" that predicts its flow and head characteristics so that the designer can then select a pump or turbine most appropriate for a particular application. Once the desired specific speed is known, basic dimensions of the unit's components can be easily calculated.

Several mathematical definitions of specific speed (all of them actually ideal-device-specific) have been created for different devices and applications.

Pump specific speed

Low-specific speed radial flow impellers develop hydraulic head principally through centrifugal force. Pumps of higher specific speeds develop head partly by centrifugal force and partly by axial force. An axial flow or propeller pump with a specific speed of 10,000 or greater generates its head exclusively through axial forces. Radial impellers are generally low flow/high head designs whereas axial flow impellers are high flow/low head designs. In theory, the discharge of a "purely" centrifugal machine (pump, turbine, fan, etc.)is tangential to the rotation of the impeller whereas a "purely" axial-flow machine's discharge will be parallel to the axis of rotation. There are also machines that exhibit a combination of both properties and are specifically referred to as "mixed-flow" machines.

Centrifugal pump impellers have specific speed values ranging from 500 to 10,000 (English units), with radial flow pumps at 500-4000, mixed flow at 2000-8000 and axial flow pumps at 7000-20,000. Values of specific speed less than 500 are associated with positive displacement pumps.

As the specific speed increases, the ratio of the impeller outlet diameter to the inlet or eye diameter decreases. This ratio becomes 1.0 for a true axial flow impeller.

where:

is specific speed (dimensionless)
is pump rotational speed (rpm)
is flowrate (l/s) at the point of best efficiency
is total head (m) per stage at the point of best efficiency

Note that the units used affect the specific speed value in the above equation and consistent units should be used for comparisons. Pump specific speed can be calculated using British gallons or using Metric units (m3/s or L/s and metres head), changing the values listed above.

The following equation gives a dimensionless specific speed.

Net suction specific speed

The net suction specific speed is mainly used to see if there will be problems with cavitation during the pump's operation on the suction side.[2] It is defined by centrifugal and axial pumps' inherent physical characteristics and operating point.[3] The net suction specific speed of a pump will define the range of operation in which a pump will experience stable operation .[4] The higher the net suction specific speed, then the smaller the range of stable operation, up to the point of cavitation at 8500 (unitless). The envelope of stable operation is defined in terms of the best efficiency point of the pump.

The net suction specific speed is defined as:[5]

where:

net suction specific speed
rotational speed of pump in rpm
flow of pump in US gallons per minute
Net positive suction head (NPSH) required in feet at pump's best efficiency point

Turbine specific speed

The specific speed value for a turbine is the speed of a geometrically similar turbine which would produce unit power (one kilowatt) under unit head (one meter).[6] The specific speed of a turbine is given by the manufacturer (along with other ratings) and will always refer to the point of maximum efficiency. This allows accurate calculations to be made of the turbine's performance for a range of heads.

Well-designed efficient machines typically use the following values: Impulse turbines have the lowest ns values, typically ranging from 1 to 10, a Pelton wheel is typically around 4, Francis turbines fall in the range of 10 to 100, while Kaplan turbines are at least 100 or more, all in imperial units.[7]


(dimensioned parameter), = rpm [8]

where:

= angular velocity (radians per second)
= Net head after turbine and waterway loss (m)
= water flow (m³/s)

English units

Expressed in English units, the "specific speed" is defined as ns = n√(P)/h5/4

Metric units

Expressed in metric units, the "specific speed" is ns = 0.2626 n√(P)/h5/4

The factor 0.2626 is only required when the specific speed is to be adjusted to English units. In countries which use the metric system, the factor is omitted, and quoted specific speeds are correspondingly larger.

Example

Given a flow and head for a specific hydro site, and the RPM requirement of the generator, calculate the specific speed. The result is the main criteria for turbine selection or the starting point for analytical design of a new turbine. Once the desired specific speed is known, basic dimensions of the turbine parts can be easily calculated.

Turbine calculations:

= Runner diameter (m)


Well-designed efficient machines typically use the following values: Impulse turbines have the lowest ns values, typically ranging from 1 to 10, a Pelton wheel is typically around 4, Francis turbines fall in the range of 10 to 100, while Kaplan turbines are at least 100 or more, all in imperial units.

See also

References

  1. Shepard, Dennis G. (1956). Principles of Turbomachinery. McMillan. ISBN 0 - 471 - 85546 - 4. LCCN 56002849.
  2. "Specific speed". McNally Institute. Retrieved 2007-07-13.
  3. "NPSH and Suction Specific Speed - Goulds Pumps - ITT Corporation". ITT Corporation. Retrieved 2007-07-13.
  4. "Article #3: Suction Specific Speed (NSS)". Pumping Machinery. Retrieved 2016-06-09.
  5. "Specific Suction Speed for Pumps". Engineering Toolbox. Retrieved 2007-07-13.
  6. http://www.thermopedia.com/content/859/
  7. "Technical derivation of basic impulse turbine physics, by J.Calvert". Mysite.du.edu. Retrieved 2012-07-08.
  8. Sayers, A. T. (1990). Hydraulic and Compressible Flow Turbomachines. Mcgraw Hill Book Co Ltd. ISBN 978-0-07-707219-3.
This article is issued from Wikipedia. The text is licensed under Creative Commons - Attribution - Sharealike. Additional terms may apply for the media files.