Perfluorocarbon tracer

Perfluorocarbon tracers (PFTs) are a range of perfluorocarbons used in tracer applications. They are used by releasing the PFT at a certain point, and determining the concentration of that PFT at another set of points, allowing the flow from the source to the points to be determined.

Properties

PFTs are believed non-toxic and chemically inert, clear, colourless liquids. They are non-flammable and are not radioactive. They do not occur in nature at all, so background levels are very low, but they can be detected at extremely low concentrations.

There is a range of PFTs available commercially, allowing the experimenter to release different PFTs at the same time. Cyclic perfluorocarbons, such as perfluoromethylhexane and perfluoro-1,3-dimethylcyclohexane, are generally believed to be better than acyclic ones as they can be detected at lower levels.

Procedure

The PFT can be released in a variety of ways, depending on the application, and may be as simple as spraying into the air. Samples are then collected at set times and locations, and either taken to a laboratory for analysis, or analysed in the field.

Analysis of the samples typically involves three parts; preparation, chromatography and detection. Preparation involves removal of other impuries, for example, mixing with hydrogen then passing over a catalyst to convert oxygen to water, which is then removed with silica gel. The sample is then admitted to a gas chromatograph. This splits up the different PFTs, so a concentration value can be determined for each one.

There are two ways PFTs are then detected; using an electron capture detector or negative ion mass spectrometry. Both techniques involve bombarding the sample with electrons, and measuring the negative ions produced. Perfluorocarbons have a particularly high affinity for electrons, so are detected in low concentrations.

An alternative set up; the chromatograph can be omitted, and the different PFTs determined from their different masses in the mass spectrum.

PFTs can be detected in concentrations as low a 1 part in 1015 by volume (1 femtolitre in a litre).[1]

Applications

Oil reservoirs are routinely mapped by injecting a PFT down one bore hole and measuring the concentration at adjacent boreholes. In this way, geologists can build up an image of the reservoir.

Traditional underground high-tension cables are constructed either with internal oil ducts or channels or by the use of a pipe through which the insulated conductor is installed. In either design the system is then filled with pressurised, de-gassed oil. The oils primary function is to improve the insulating properties of the cable but occasionally leaks can occur through cable joints, oil system fittings or cable sheath damage. The leak is initially identified by the loss of liquid from the system, but its location used to involve engineers digging up the road, freezing a section of cable and seeing if the level was still going down, then choosing a new point to dig and re-freeze. It could take several holes to isolate the leak. If a PFT is injected into the oil, there will be a relatively high concentration of PFT above the leak, which can be pin-pointed to within a few feet, requiring only a single hole to be dug right where the leak is.[2]

PFTs have been used to follow air movement, for tracing the flow of pollutants, for example, the Big Bend Regional Aerosol and Visibility Observational study.[3] measuring the effectiveness of ventilation and studying the possible effects of terrorist attacks (for example in New York ).[4]

PFTs have even been used to track ransom money after a kidnapping.[5]

References

  1. "Instrumentation". University of Bristol Atmospheric Chemistry Research Group.
  2. Ghafurian, R.; Dietz, R.N.; Rodenbaugh, T.; Dominguez, J.; Tai, N. (1999). "Leak location in fluid filled cables using the PFT method" (PDF). IEEE Transactions on Power Delivery. 14: 18. doi:10.1109/61.736673.
  3. Schichtel, Bret A.; Barna, Michael G.; Gebhart, Kristi A.; Malm, William C. (2005). "Evaluation of a Eulerian and Lagrangian air quality model using perfluorocarbon tracers released in Texas for the BRAVO haze study" (PDF). Atmospheric Environment. 39 (37): 7044. doi:10.1016/j.atmosenv.2005.08.015.
  4. "Anatomy on a test on terror" (PDF).
  5. "Demonstration of the Use of an Encapsulated Perfluorocarbon Vapor Taggant to Track and Detect Currency or Contraband, Final Report" (PDF).
This article is issued from Wikipedia. The text is licensed under Creative Commons - Attribution - Sharealike. Additional terms may apply for the media files.