HAZMAT Class 5 Oxidizing agents and organic peroxides
An oxidizer is a chemical that readily yields oxygen in reactions, thereby causing or enhancing combustion.
Divisions
Division 5.1: Oxidizers
An oxidizer is a material that may, generally by yielding oxygen, cause or enhance the combustion of other materials.
- A solid material is classed as a Division 5.1 material if, when tested in accordance with the UN Manual of Tests and Criteria, its mean burning time is less than or equal to the burning time of a 3:7 potassium bromate/cellulose mixture.
- A liquid material is classed as a Division 5.1 material if, when tested in accordance with the UN Manual of Tests and Criteria, it spontaneously ignites or its mean time for a pressure rise from 690 kPa to 2070 kPa gauge is less than the time of a 1:1 nitric acid (65 percent)/cellulose mixture.
Division 5.2: Organic Peroxides
An organic peroxide is any organic compound containing oxygen (O) in the bivalent -O-O- structure and which may be considered a derivative of hydrogen peroxide, where one or more of the hydrogen atoms have been replaced by organic radicals, unless any of the following paragraphs applies:
- The material meets the definition of an explosive as prescribed in subpart C of this part, in which case it must be classed as an explosive (applies to acetone peroxide, for example)
- The material is forbidden from being offered for transportation according to 49CFR 172.101 of this subchapter or 49CFR 173.21;
- The Associate Administrator for Hazardous Materials Safety has determined that the material does not present a hazard which is associated with a Division 5.2 material; or
- The material meets one of the following conditions:
- For materials containing no more than 1.0 percent hydrogen peroxide, the available oxygen, as calculated using the equation in paragraph (a)(4)(ii) of this section, is not more than 1.0 percent, or
- For materials containing more than 1.0 percent but not more than 7.0 percent hydrogen peroxide, the available oxygen content (Oa) is not more than 0.5 percent, when determined using the equation:
- Oa = 16x
- where for a material containing k species of organic peroxides:
- = number of -O-O- groups per molecule of the species
- = concentration (mass percent) of the species
- = molecular mass of the species
Placards
|
|
The yellow symbol is incorrect for 5.2 new symbol has a red upper half and a yellow lower half. Flame symbol in the upper half
Compatibility Table
Load and Segregation Chart | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Weight | 1.1 | 1.2 | 1.3 | 1.4 | 1.5 | 1.6 | 2.1 | 2.2 | 2.2 | 2.3 | 3 | 4.1 | 4.2 | 4.3 | 5.1 | 5.2 | 6.1 | 7 | 8 | |||
A | B | A | ||||||||||||||||||||
5.1 | 1001 lb | A | X | X | X | X | X | O | O | X | O | |||||||||||
5.2 | 1001 lb | X | X | X | X | X | O | X | O | |||||||||||||
Key | ||||||||||||||||||||||
The absence of any hazard class or division or a blank space in the table indicates that no restrictions apply.
|
Packing Groups
Class 5 Packing Groups | |||
---|---|---|---|
Group | Division | Phase | Details |
Group I | 5.1 | Solid | Any material which, in either concentration tested, exhibits a mean burning time less than the mean burning time of a 3:2 potassium bromate/cellulose mixture. |
Group II | 5.1 | Solid | Any material which, in either concentration tested, exhibits a mean burning time less than or equal to the mean burning time of a 2:3 potassium bromate/cellulose mixture and the criteria for Packing Group I are not met. |
Group III | 5.1 | Solid | Any material which, in either concentration tested, exhibits a mean burning time less than or equal to the mean burning time of a 3:7 potassium bromate/cellulose mixture and the criteria for Packing Group I and II are not met. |
Group I | 5.1 | Liquid |
|
Group II | 5.1 | Liquid | Any material which exhibits a mean pressure rise time less than or equal to the pressure rise time of a 1:1 aqueous sodium chlorate solution(40 percent)/cellulose mixture and the criteria for Group I are not met. |
Group III | 5.1 | Liquid | Any material which exhibits a mean pressure rise time less than or equal to the pressure rise time of a 1:1 nitric acid (65 percent)/cellulose mixture and the criteria for Packing Group I and II are not met. |
Group II | 5.2 | All | All Division 5.2 materials are assigned to Packing Group II in Column 5 of the 49 CFR 172.101 Table. |
References
- 49 CFR 173.127(a)
- 49 CFR 173.128(a)
This article is issued from
Wikipedia.
The text is licensed under Creative Commons - Attribution - Sharealike.
Additional terms may apply for the media files.