Flicker fusion threshold
The flicker fusion threshold (or flicker fusion rate) is a concept in the psychophysics of vision. It is defined as the frequency at which an intermittent light stimulus appears to be completely steady to the average human observer. Flicker fusion threshold is related to persistence of vision. Although flicker can be detected for many waveforms representing time-variant fluctuations of intensity, it is conventionally, and most easily, studied in terms of sinusoidal modulation of intensity. There are seven parameters that determine the ability to detect the flicker:
- the frequency of the modulation;
- the amplitude or depth of the modulation (i.e., what is the maximum percent decrease in the illumination intensity from its peak value);
- the average (or maximum—these can be inter-converted if modulation depth is known) illumination intensity;
- the wavelength (or wavelength range) of the illumination (this parameter and the illumination intensity can be combined into a single parameter for humans or other animals for which the sensitivities of rods and cones are known as a function of wavelength using the luminous flux function);
- the position on the retina at which the stimulation occurs (due to the different distribution of photoreceptor types at different positions);
- the degree of light or dark adaptation, i.e., the duration and intensity of previous exposure to background light, which affects both the intensity sensitivity and the time resolution of vision;
- physiological factors such as age and fatigue.[1]
Explanation
As long as the modulation frequency is kept above the fusion threshold, the perceived intensity can be changed by changing the relative periods of light and darkness. One can prolong the dark periods and thus darken the image; therefore the effective and average brightness are equal. This is known as the Talbot-Plateau law.[2] Like all psychophysical thresholds, the flicker fusion threshold is a statistical rather than an absolute quantity. There is a range of frequencies within which flicker sometimes will be seen and sometimes will not be seen, and the threshold is the frequency at which flicker is detected on 50% of trials.
Different points in the visual system have very different critical flicker fusion rate (CFF) sensitivities; the overall threshold frequency for perception cannot exceed the slowest of these for a given modulation amplitude. Each cell type integrates signals differently. For example, rod photoreceptor cells, which are exquisitely sensitive and capable of single-photon detection, are very sluggish, with time constants in mammals of about 200 ms. Cones, in contrast, while having much lower intensity sensitivity, have much better time resolution than rods do. For both rod- and cone-mediated vision, the fusion frequency increases as a function of illumination intensity, until it reaches a plateau corresponding to the maximal time resolution for each type of vision. The maximal fusion frequency for rod-mediated vision reaches a plateau at about 15 Hz, whereas cones reach a plateau, observable only at very high illumination intensities, of about 60 Hz[3][4]
In addition to increasing with average illumination intensity, the fusion frequency also increases with the extent of modulation (the maximal relative decrease in light intensity presented); for each frequency and average illumination, there is a characteristic modulation threshold, below which the flicker cannot be detected, and for each modulation depth and average illumination, there is a characteristic frequency threshold. It should be noted that these values vary with the wavelength of illumination, because of the wavelength dependence of photoreceptor sensitivity, and they vary with the position of the illumination within the retina, because of the concentration of cones in central regions including the fovea and the macula, and the dominance of rods in the peripheral regions of the retina.
The flicker fusion threshold is proportional to the amount of modulation; if brightness is constant, a brief flicker will manifest a much lower threshold frequency than a long flicker. The threshold also varies with brightness (it is higher for a brighter light source) and with location on the retina where the perceived image falls: the rod cells of the human eye have a faster response time than the cone cells, so flicker can be sensed in peripheral vision at higher frequencies than in foveal vision. This is essentially the concept known as the Ferry-Porter law, where it may take some increase in brightness, by powers of ten, to require as many as 60 flashes to achieve fusion, while for rods, it may take as little as four flashes, since in the former case each flash is easily cut off, and in the latter it lasts long enough, even after 1/4 second, to merely prolong it and not intensify it.[2] From a practical point of view, if a stimulus is flickering, such as computer monitor, decreasing the intensity level will eliminate the flicker.[5] The flicker fusion threshold also is lower for a fatigued observer. Decrease in the critical fusion frequency has often been used as an index of central fatigue.[6]
Technological considerations
Display frame rate
Flicker fusion is important in all technologies for presenting moving images, nearly all of which depend on presenting a rapid succession of static images (e.g. the frames in a cinema film, TV show, or a digital video file). If the frame rate falls below the flicker fusion threshold for the given viewing conditions, flicker will be apparent to the observer, and movements of objects on the film will appear jerky. For the purposes of presenting moving images, the human flicker fusion threshold is usually taken between 60 and 90 hertz (Hz), though in certain cases it can be higher by an order of magnitude.[7] In practice, movies are recorded at 24 frames per second and displayed by repeating each frame two or three times for a flicker of 48 or 72 Hz. Standard-definition television operates at 25 or 30 frames per second, or sometimes at 50 or 60 (half-)frames per second through interlacing. High-definition video is displayed at 24, 25, 30, 60 frames per second or higher.
Display refresh rate
CRT displays usually by default operated at a vertical scan rate of 60 Hz, which often resulted in noticeable flicker. Many systems allowed increasing the rate to higher values such as 72, 75 or 100 Hz to avoid this problem. Most people do not detect flicker above 400 Hz.[8] Other display technologies do not flicker noticeably, so the frame rate is less important. LCD flat panels do not seem to flicker at all, as the backlight of the screen operates at a very high frequency of nearly 200 Hz, and each pixel is changed on a scan rather than briefly turning on and then off as in CRT displays. However, the nature of the back-lighting used can induce flicker – LEDs cannot be easily dimmed, and therefore use pulse-width modulation to create the illusion of dimming, and the frequency used can be perceived as flicker by sensitive users.[9][10][11]
Lighting
Flicker is also important in the field of domestic (alternating current) lighting, where noticeable flicker can be caused by varying electrical loads, and hence can be very disturbing to electric utility customers. Most electricity providers have maximum flicker limits that they try to meet for domestic customers.
Fluorescent lamps using conventional magnetic ballasts flicker at twice the supply frequency. Electronic ballasts do not produce light flicker since the phosphor persistence is longer than a half cycle of the higher operation frequency of 20 kHz. The 100–120 Hz flicker produced by magnetic ballasts is associated with headaches and eyestrain.[12] Individuals with high critical flicker fusion threshold are particularly affected by light from fluorescent fixtures that have magnetic ballasts: their EEG alpha waves are markedly attenuated and they perform office tasks with greater speed and decreased accuracy. The problems are not observed with electronic ballasts.[13] Ordinary people have better reading performance using high-frequency (20–60 kHz) electronic ballasts than magnetic ballasts,[14] although the effect was small except at high contrast ratio.
The flicker of fluorescent lamps, even with magnetic ballasts, is so rapid that it is unlikely to present a hazard to individuals with epilepsy.[15] Early studies suspected a relationship between the flickering of fluorescent lamps with magnetic ballasts and repetitive movement in autistic children.[16] However, these studies had interpretive problems[17] and have not been replicated.
Visual phenomena
In some cases, it is possible to indirectly detect flicker at rates well beyond 60 Hz in the case of high-speed motion, via the "phantom array" effect.[18] Fast-moving flickering objects zooming across view (either by object motion, or by eye motion such as rolling eyes), can cause a dotted or multicolored blur instead of a continuous blur, as if they were multiple objects.[19] Stroboscopes are sometimes used to induce this effect intentionally. Some special effects, such as certain kinds of electronic glowsticks commonly seen at outdoor events, have the appearance of a solid color when motionless but produce a multicolored or dotted blur when waved about in motion. These are typically LED-based glow sticks. The variation of the duty cycle upon the LED(s), results in usage of less power while by the properties of flicker fusion having the direct effect of varying the brightness. When moved, if the frequency of duty cycle of the driven LED(s) is below the flicker fusion threshold timing differences between the on/off state of the LED(s) becomes evident, and the color(s) appear as evenly spaced points in the peripheral vision.
A related phenomenon is the DLP Rainbow Effect, where different colors are displayed in different places on the screen for the same object due to fast motion.
The stroboscopic effect is sometimes used to "stop motion" or to study small differences in repetitive motions.
Non-human species
The flicker fusion threshold also varies between species. Pigeons have been shown to have higher threshold than humans (100 Hz vs. 60 Hz), and the same is probably true for all birds, particularly birds of prey.[20] Many mammals have a higher proportion of rods in their retinae than humans do, and it is likely that they would also have higher flicker fusion thresholds. This has been confirmed in dogs.[21] Research also shows that size and metabolic rate are two factors that come into play.[22][23]
See also
References
- ↑ S.W. Davis, Auditory and Visual Flicker-Fusion as Measures of Fatigue, The American Journal of Psychology, Vol. 68. No. 4. Dec., 1955
- 1 2 "eye, human."Encyclopædia Britannica. 2008. Encyclopædia Britannica 2006 Ultimate Reference Suite DVD
- ↑ INTERMITTENT STIMULATION BY LIGHT : V. THE RELATION BETWEEN INTENSITY AND CRITICAL FREQUENCY FOR DIFFERENT PARTS OF THE SPECTRUM. Hecht S, Shlaer S. J Gen Physiol. 1936 Jul 20;19(6):965–77.
- ↑ "[Neuroscience] Re: Flicker Fusion Threshold Examples". Bio.net. Retrieved 2013-05-05.
- ↑ "Temporal Resolution – Webvision". Webvision.med.utah.edu. 2011-03-30. Retrieved 2013-05-05.
- ↑ Ernst Simonson and Norbert Enzer, Measurement of fusion frequency of flicker as a test for fatigue of the central nervous system, J. Indus. Hyg. Tox., 23, 1941, 83–89.
- ↑ James Davis (1986), "Humans perceive flicker artefacts at 500 Hz", Sci Rep, Wiley, 5: 7861, PMC 4314649 , PMID 25644611, doi:10.1038/srep07861
- ↑ Chase, Ronald (1974). "The Initiation and Conduction of Action Potentials in the Optic Nerve of Tritonia". Journal of Experimental Biology. 60: 721–734.
- ↑ "PSA: LED-Backlighting Can Cause Migraine Headaches". CrispyCromar.com. Retrieved 2013-05-05.
- ↑ View: Everyone Only Notes (2008-08-23). "Eye strain from LED backlighting in...: Apple Support Communities". Discussions.apple.com. Retrieved 2013-05-05.
- ↑ Wilkins, Veitch & Lehman (2010). "LED Lighting Flicker and Potential Health Concerns: IEEE Standard PAR1789 Update" (PDF). University of Essex, UK. Retrieved 2014-07-01.
- ↑ "Full-spectrum Fluorescent lighting : A review of its effects on physiology and health". Retrieved 2008-04-23.
- ↑ Küller R, Laike T (1998). "The impact of flicker from fluorescent lighting on well-being, performance and physiological arousal". Ergonomics. 41 (4): 433–47. PMID 9557586. doi:10.1080/001401398186928.
- ↑ Veitch JA, McColl SL (1995). "Modulation of fluorescent light: flicker rate and light source effects on visual performance and visual comfort" (PDF). Light Res Tech. 27 (4): 243–256. doi:10.1177/14771535950270040301. Retrieved 2012-06-28.
- ↑ Binnie CD, de Korte RA, Wisman T (1979). "Fluorescent lighting and epilepsy". Epilepsia. 20 (6): 725–7. PMID 499117. doi:10.1111/j.1528-1157.1979.tb04856.x.
- ↑ Colman RS, Frankel F, Ritvo E, Freeman BJ (1976). "The effects of fluorescent and incandescent illumination upon repetitive behaviors in autistic children". J Autism Child Schizophr. 6 (2): 157–62. PMID 989489. doi:10.1007/BF01538059.
- ↑ Turner M (1999). "Annotation: Repetitive behaviour in autism: a review of psychological research". J Child Psychol Psychiatry. 40 (6): 839–49. PMID 10509879. doi:10.1017/S0021963099004278.
- ↑ http://opensiuc.lib.siu.edu/cgi/viewcontent.cgi?article=1538&context=tpr
- ↑ http://www.thenakedscientists.com/forum/index.php?topic=45126.0 |A visually accurate description of the ghosting/ phantom array effect
- ↑ (Winkler 2005)
- ↑ "A Dog’s Eye View | On Point with Tom Ashbrook". Onpoint.wbur.org. Archived from the original on October 20, 2013. Retrieved 2013-05-05.
- ↑ Kevin Healy; Luke McNally; Graeme D. Ruxton; Natalie Cooper; Andrew L. Jackson (2013-10-01). "Metabolic rate and body size linked with perception of temporal information". Elsevier. Retrieved 2014-08-06.
- ↑ The Economist (2013-09-21). "Slo-mo mojo: How animals perceive time". London: Economist. Retrieved 2013-10-20.
- Winkler, Robert (2005-11-13). "The Need for Speed". The New York Times.
- Winkler, Robert. "The Flicker Fusion Factor: Why we can't drive safely at high speed". Archived from the original on 2010-12-05, repost on author's personal website.
- I get it, I know I'm inferior, November 9, 2006, Pharyngula – comments
External links
- IEC Flicker Meter
- The Flicker Fusion Factor Why we can't drive safely at high speed
- Webvision's section concerning the psychophysics of time in vision