Equivalent potential temperature

Equivalent potential temperature, commonly referred to as theta-e , is a quantity that is conserved during changes to an air parcel's pressure (that is, during vertical motions in the atmosphere), even if water vapor condenses during that pressure change. It is therefore more conserved than the ordinary potential temperature, which remains constant only for unsaturated vertical motions (pressure changes).

is the temperature a parcel of air would reach if all the water vapor in the parcel were to condense, releasing its latent heat, and the parcel was brought adiabatically to a standard reference pressure, usually 1000 hPa (1000 mbar) which is roughly equal to atmospheric pressure at sea level.

Its use in estimating atmospheric stability

Stability of incompressible fluid

Like a ball balanced on top of a hill, denser fluid lying above less dense fluid would be dynamically unstable: overturning motions (convection) can lower the center of gravity, and thus will occur spontaneously, rapidly producing a stable stratification which is thus the observed condition almost all the time. The condition for stability of an incompressible fluid is that density decreases monotonically with height.

Stability of compressible air: potential temperature

If a fluid is compressible like air, the criterion for dynamic stability instead involves potential density, the density of the fluid at a fixed reference pressure. For an ideal gas (see gas laws), the stability criterion for an air column is that potential temperature increases monotonically with height.

To understand this, consider dry convection in the atmosphere, where the vertical variation in pressure is substantial and adiabatic temperature change is important: As a parcel of air moves upward, the ambient pressure drops, causing the parcel to expand. Some of the internal energy of the parcel is used up in doing the work required to expand against the atmospheric pressure, so the temperature of the parcel drops, even though it has not lost any heat. Conversely, a sinking parcel is compressed and becomes warmer even though no heat is added.

Air at the top of a mountain is usually colder than the air in the valley below, but the arrangement is not unstable: if a parcel of air from the valley were somehow lifted up to the top of the mountain, when it arrived it would be even colder than the air already there, due to adiabatic cooling; it would be heavier than the ambient air, and would sink back toward its original position. Similarly, if a parcel of cold mountain-top air were to make the trip down to the valley, it would arrive warmer and lighter than the valley air, and would float back up the mountain.

So cool air lying on top of warm air can be stable, as long as the temperature decrease with height is less than the adiabatic lapse rate; the dynamically important quantity is not the temperature, but the potential temperaturethe temperature the air would have if it were brought adiabatically to a reference pressure. The air around the mountain is stable because the air at the top, due to its lower pressure, has a higher potential temperature than the warmer air below.

Effects of water condensation: equivalent potential temperature

A rising parcel of air containing water vapor, if it rises far enough, reaches its lifted condensation level: it becomes saturated with water vapor (see Clausius–Clapeyron relation). If the parcel of air continues to rise, water vapor condenses and releases its latent heat to the surrounding air, partially offsetting the adiabatic cooling. A saturated parcel of air therefore cools less than a dry one would as it rises (its temperature changes with height at the moist adiabatic lapse rate, which is smaller than the dry adiabatic lapse rate). Such a saturated parcel of air can achieve buoyancy, and thus accelerate further upward, a runaway condition (instability) even if potential temperature increases with height. The sufficient condition for an air column to be absolutely stable, even with respect to saturated convective motions, is that the equivalent potential temperature must increase monotonically with height.

Formula

A number of approximate formulations are used for calculating equivalent potential temperature, since it is not easy to compute integrations along motion of the parcel. Bolton (1980) [1] gives review of such procedures with estimates of error. His best approximation formula is used when accuracy is needed:

Where:

A little more theoretical formula is commonly used in literature like Holton (1972) [3] when theoretical explanation is important:

Where:

Further more simplified formula is used (in, for example, Stull 1988[4] §13.1 p. 546) for simplicity, if it is desirable to avoid computing :

Where:

Usage

Back trajectories of air masses between December 31, 1997, and January 1998 which caused the North American Ice Storm of 1998

This applies on the synoptic scale for characterisation of air masses. For instance, in a study of the North American Ice Storm of 1998, professors Gyakum (McGill University, Montreal) and Roebber (Wisconsin University, Milwaukee) have demonstrated that the air masses involved originated from high Arctic at an altitude of 300 to 400 hPa the previous week, went down toward the surface as they moved to the Tropics, then moved back up along the Mississippi Valley toward the St. Lawrence Valley. The back trajectories were evaluated using the constant equivalent potential temperatures.[5]

In the mesoscale, equivalent potential temperature is also a useful measure of the static stability of the unsaturated atmosphere. Under normal, stably stratified conditions, the potential temperature increases with height,

and vertical motions are suppressed. If the equivalent potential temperature decreases with height,

the atmosphere is unstable to vertical motions, and convection is likely. Situations in which the equivalent potential temperature decreases with height, indicating instability in saturated air, are quite common.

See also

Bibliography

References

  1. D Bolton, 1980: The Computation of Equivalent Potential Temperature. Mon. Wea. Rev., Vol. 108, pp.1046-1053.
  2. Met Office. "Data processing procedure". E-AMDAR Evaluation. World Meteorological Organisation. Retrieved 2009-08-02.
  3. J R Holton, An Introduction to Dynamical Meteorology. Academic Press, 1972, 319 pages.
  4. R B Stull, An Introduction to Boundary Layer Meteorology, Kluwer, 1988, 666 pages, ISBN 9027727694.
  5. Gyakum, John R.; Roebber, Paul J. (December 2001). "The 1998 Ice Storm, Analysis of a Planetary-Scale Event" (pdf). Monthly Weather Review. American Meteorological Society. 129 (12): 2983–2997. Bibcode:2001MWRv..129.2983G. doi:10.1175/1520-0493(2001)129<2983:TISAOA>2.0.CO;2. Retrieved 19 June 2012..
This article is issued from Wikipedia. The text is licensed under Creative Commons - Attribution - Sharealike. Additional terms may apply for the media files.