Convective available potential energy
In meteorology, convective available potential energy (CAPE),[1] sometimes, simply, available potential energy (APE), is the amount of energy a parcel of air would have if lifted a certain distance vertically through the atmosphere. CAPE is effectively the positive buoyancy of an air parcel and is an indicator of atmospheric instability, which makes it very valuable in predicting severe weather. It is a form of fluid instability found in thermally stratified atmospheres in which a colder fluid overlies a warmer one. As explained below, when an air mass is unstable, the element of the air mass that is displaced upwards is accelerated by the pressure differential between the displaced air and the ambient air at the (higher) altitude to which it was displaced. This usually creates vertically developed clouds from convection, due to the rising motion, which can eventually lead to thunderstorms. It could also be created by other phenomena, such as a cold front. Even if the air is cooler on the surface, there is still warmer air in the mid-levels, that can rise into the upper-levels. However, if there is not enough water vapor present, there is no ability for condensation, thus storms, clouds, and rain will not form.
Mechanics
CAPE exists within the conditionally unstable layer of the troposphere, the free convective layer (FCL), where an ascending air parcel is warmer than the ambient air. CAPE is measured in joules per kilogram of air (J/kg). Any value greater than 0 J/kg indicates instability and an increasing possibility of thunderstorms and hail. Generic CAPE is calculated by integrating vertically the local buoyancy of a parcel from the level of free convection (LFC) to the equilibrium level (EL):
Where is the height of the level of free convection and is the height of the equilibrium level(neutral buoyancy), where is the virtual temperature of the specific parcel, where is the virtual temperature of the environment, and where is the acceleration due to gravity. CAPE for a given region is most often calculated from a thermodynamic or sounding diagram (e.g., a Skew-T log-P diagram) using air temperature and dew point data usually measured by a weather balloon.
CAPE is effectively positive buoyancy, expressed B+ or simply B; the opposite of convective inhibition (CIN), which is expressed as B-, and can be thought of as "negative CAPE". As with CIN, CAPE is usually expressed in J/kg but may also be expressed as m2/s2, as the values are equivalent. In fact, CAPE is sometimes referred to as positive buoyant energy (PBE). This type of CAPE is the maximum energy available to an ascending parcel and to moist convection. When a layer of CIN is present, the layer must be eroded by surface heating or mechanical lifting, so that convective boundary layer parcels may reach their level of free convection (LFC).
On a sounding diagram, CAPE is the positive area above the LFC, the area between the parcel's virtual temperature line and the environmental virtual temperature line where the ascending parcel is warmer than the environment. Neglecting the virtual temperature correction may result in substantial relative errors in the calculated value of CAPE for small CAPE values.[2] CAPE may also exist below the LFC, but if a layer of CIN (subsidence) is present, it is unavailable to deep, moist convection until CIN is exhausted. When there is mechanical lift to saturation, cloud base begins at the lifted condensation level (LCL); absent forcing, cloud base begins at the convective condensation level (CCL) where heating from below causes spontaneous buoyant lifting to the point of condensation when the convective temperature is reached. When CIN is absent or is overcome, saturated parcels at the LCL or CCL, which had been small cumulus clouds, will rise to the LFC, and then spontaneously rise until hitting the stable layer of the equilibrium level. The result is deep, moist convection (DMC), or simply, a thunderstorm.
When a parcel is unstable, it will continue to move vertically, in either direction, dependent on whether it receives upward or downward forcing, until it reaches a stable layer (though momentum, gravity, and other forcing may cause the parcel to continue). There are multiple types of CAPE, downdraft CAPE (DCAPE), estimates the potential strength of rain and evaporatively cooled downdrafts. Other types of CAPE may depend on the depth being considered. Other examples are surface based CAPE (SBCAPE), mixed layer or mean layer CAPE (MLCAPE), most unstable or maximum usable CAPE (MUCAPE), and normalized CAPE (NCAPE).[3]
Fluid elements displaced upwards or downwards in such an atmosphere expand or compress adiabatically in order to remain in pressure equilibrium with their surroundings, and in this manner become less or more dense.
If the adiabatic decrease or increase in density is less than the decrease or increase in the density of the ambient (not moved) medium, then the displaced fluid element will be subject to downwards or upwards pressure, which will function to restore it to its original position. Hence, there will be a counteracting force to the initial displacement. Such a condition is referred to as convective stability.
On the other hand, if adiabatic decrease or increase in density is greater than in the ambient fluid, the upwards or downwards displacement will be met with an additional force in the same direction exerted by the ambient fluid. In these circumstances, small deviations from the initial state will become amplified. This condition is referred to as convective instability.[4]
Convective instability is also termed static instability, because the instability does not depend on the existing motion of the air; this contrasts with dynamic instability where instability is dependent on the motion of air and its associated effects such as dynamic lifting.
Significance to thunderstorms
Thunderstorms form when air parcels are lifted vertically. Deep, moist convection requires a parcel to be lifted to the LFC where it then rises spontaneously until reaching a layer of non-positive buoyancy. The atmosphere is warm at the surface and lower levels of the troposphere where there is mixing (the planetary boundary layer (PBL)), but becomes substantially cooler with height. The temperature profile of the atmosphere, the change in temperature, the degree that it cools with height, is the lapse rate. When the rising air parcel cools more slowly than the surrounding atmosphere, it remains warmer and less dense. The parcel continues to rise freely (convectively; without mechanical lift) through the atmosphere until it reaches an area of air less dense (warmer) than itself.
The amount, and shape, of the positive-buoyancy area modulates the speed of updrafts, thus extreme CAPE can result in explosive thunderstorm development; such rapid development usually occurs when CAPE stored by a capping inversion is released when the "lid" is broken by heating or mechanical lift. The amount of CAPE also modulates how low-level vorticity is entrained and then stretched in the updraft, with importance to tornadogenesis. The most important CAPE for tornadoes is within the lowest 1 to 3 km (0.6 to 1.9 mi) of the atmosphere, whilst deep layer CAPE and the width of CAPE at mid-levels is important for supercells. Tornado outbreaks tend to occur within high CAPE environments. Large CAPE is required for the production of very large hail, owing to updraft strength, although a rotating updraft may be stronger with less CAPE. Large CAPE also promotes lightning activity.[5]
Two notable days for severe weather exhibited CAPE values over 5 kJ/kg. Two hours before the 1999 Oklahoma tornado outbreak occurred on May 3, 1999, the CAPE value sounding at Oklahoma City was at 5.89 kJ/kg. A few hours later, an F5 tornado ripped through the southern suburbs of the city. Also on May 4, 2007 CAPE values of 5.5 kJ/kg were reached and an EF5 tornado tore through Greensburg, Kansas. On these days, it was apparent that conditions were ripe for tornadoes and CAPE wasn't a crucial factor. However, extreme CAPE, by modulating the updraft (and downdraft), can allow for exceptional events, such as the deadly F5 tornadoes that hit Plainfield, Illinois on August 28, 1990 and Jarrell, Texas on May 27, 1997 on days which weren't readily apparent as conducive to large tornadoes. CAPE was estimated to exceed 8 kJ/kg in the environment of the Plainfield storm and was around 7 kJ/kg for the Jarrell storm.
Severe weather and tornadoes can develop in an area of low CAPE values. The surprise severe weather event that occurred in Illinois and Indiana on April 20, 2004 is a good example. Importantly in that case, was that although overall CAPE was weak, there was strong CAPE in the lowest levels of the troposphere which enabled an outbreak of minisupercells producing large, long-track, intense tornadoes.[6]
Example from meteorology
A good example of convective instability can be found in our own atmosphere. If dry mid-level air is drawn over very warm, moist air in the lower troposphere, a hydrolapse (an area of rapidly decreasing dew point temperatures with height) results in the region where the moist boundary layer and mid-level air meet. As daytime heating increases mixing within the moist boundary layer, some of the moist air will begin to interact with the dry mid-level air above it. Owing to thermodynamic processes, as the dry mid-level air is slowly saturated its temperature begins to drop, increasing the adiabatic lapse rate. Under certain conditions, the lapse rate can increase significantly in a short amount of time, resulting in convection. High convective instability can lead to severe thunderstorms and tornadoes as moist air which is trapped in the boundary layer eventually becomes highly negatively buoyant relative to the adiabatic lapse rate and escapes as a rapidly rising bubble of humid air triggering the development of a cumulus or cumulonimbus cloud.
See also
References
- ↑ M. W. Moncrieff, M.J. Miller (1976). "The dynamics and simulation of tropical cumulonimbus and squall lines". Q. J. R. Meteorol. Soc. 120 (432): 373–94. Bibcode:1976QJRMS.102..373M. doi:10.1002/qj.49710243208.
- ↑ Charles A. Doswell III, E.N. Rasmussen (December 1994). "The Effect of Neglecting the Virtual Temperature Correction on CAPE Calculations". Weather and Forecasting. 9 (4): 625–9. Bibcode:1994WtFor...9..625D. doi:10.1175/1520-0434(1994)009<0625:TEONTV>2.0.CO;2.
- ↑ Thompson, Rich (2006). "Explanation of SPC Severe Weather Parameters". Storm Prediction Center. Retrieved 2007-05-30.
- ↑ Shu, Frank (1992). The Physics of Astrophysics, volume II: Gas dynamics. University Science Books. ISBN 0-935702-65-2.
- ↑ Craven, Jeffrey P.; H.E. Brooks (December 2004). "Baseline climatology of sounding derived parameters associated with deep moist convection" (PDF). National Weather Digest. National Weather Association. 28: 13–24.
- ↑ Pietrycha, Albert E.; J.M. Davies; M. Ratzer; P. Merzlock (October 2004). "Tornadoes in a Deceptively Small CAPE Environment: The 4/20/04 Outbreak in Illinois and Indiana". Preprints of the 22nd Conference on Severe Local Storms. Hyannis, Massachusetts: American Meteorological Society.
Further reading
- Barry, R.G. and Chorley, R.J. Atmosphere, weather and climate (7th ed) Routledge 1998 p. 80-81 ISBN 0-415-16020-0