Beverly Clock

The Beverly Clock as it now stands in the Physics Department at the University of Otago
The inner mechanism of the Beverly clock showing chain, sprockets and torsional pendulum

The Beverly Clock[1] is a clock situated in the 3rd floor lift foyer of the Department of Physics at the University of Otago, Dunedin, New Zealand. The clock is still running despite never having been manually wound since its construction in 1865 by Arthur Beverly.[2]

Operation

The clock's mechanism is driven by variations in atmospheric pressure, and by daily temperature variations; of the two, temperature variations are more important. Either causes the air in a one cubic-foot (28 litre) air-tight box to expand or contract, which pushes on a diaphragm. A temperature variation of six degrees Fahrenheit (3.3K) over the course of each day creates approximately enough pressure to raise a one-pound weight by one inch, which drives the clock mechanism.

A similar mechanism in a commercially available clock which operates on the same principle is the Atmos clock, which is manufactured by the Swiss watchmaker Jaeger-LeCoultre.

While the clock has not been wound since it was made by Arthur Beverly in 1864, it has stopped on a number of occasions, such as when its mechanism needed cleaning or there was a mechanical failure, and when the Physics Department moved to new quarters. As well, on occasions when the ambient temperature has not fluctuated sufficiently to absorb the requisite amount of energy, the clock will not function. However, after environmental parameters readjust, the clock begins operating again.

See also

References

Citations
General
This article is issued from Wikipedia. The text is licensed under Creative Commons - Attribution - Sharealike. Additional terms may apply for the media files.