NPIV

NPIV or N_Port ID Virtualization is a Fibre Channel feature whereby multiple Fibre Channel node port (N_Port) IDs can share a single physical N_Port. This allows multiple Fibre Channel initiators to occupy a single physical port, easing hardware requirements in Storage Area Network (SAN) design, especially where virtual SANs are called for. This allows each virtual server to see its own storage and no other virtual server's storage.[1] NPIV is defined by the Technical Committee T11 in the Fibre Channel - Link Services (FC-LS) specification.

N_Port initialization with and without NPIV

Normally N_Port initialization proceeds like this:

However with NPIV it may continue like this:

FDISC is an abbreviation for Fabric Discovery, or "Discover Fabric Service Parameters", which is a misleading name in this context. It works just like FLOGI.

Notes

Sources

This article is issued from Wikipedia - version of the Tuesday, July 08, 2014. The text is available under the Creative Commons Attribution/Share Alike but additional terms may apply for the media files.