ESR meter
An ESR meter is a two-terminal electronic measuring instrument designed and used primarily to measure the equivalent series resistance (ESR) of real capacitors; usually without the need to disconnect the capacitor from the circuit it is connected to. Other types of meter used for routine servicing, including normal capacitance meters, cannot be used to measure a capacitor's ESR, although a few combined meters are available which measure both ESR and out-of-circuit capacitance. A standard (DC) milliohmmeter cannot be used to measure ESR, because a steady direct current cannot be passed through the capacitor.
Most ESR meters can also be used to measure non-inductive low-value resistances, whether or not associated with a capacitor; this leads to a number of additional applications described below.
Need for ESR measurement
Aluminium electrolytic capacitors have a relatively high ESR that increases with age, heat, and ripple current; this can cause the equipment using them to malfunction. In older equipment, this tended to cause hum and degraded operation; modern equipment, in particular switch-mode power supplies, is very sensitive to ESR, and a capacitor with high ESR can cause equipment to malfunction or cause permanent damage requiring repair, typically by causing power supply voltages to become excessively high.[1] This type of capacitor is very often used because it is inexpensive and has a very high capacitance per unit volume or weight; typically, these capacitors have capacitance from about one microfarad to tens of thousands of microfarads.
Capacitors with faults leading to high ESR often bulge and leak, making them easy to identify visually; however, capacitors that appear visually perfect may still have high ESR, detectable only by measurement.
Precise measurement of ESR is rarely necessary, and any usable meter is adequate for troubleshooting. Where precision is required, measurements must be taken under appropriately specified conditions, because ESR varies with frequency, applied voltage, and temperature. A general-purpose ESR meter operating with a fixed waveform is unlikely to be suitable for precise laboratory measurements.
Methods of ESR measurement
Measuring ESR can be done by applying an alternating voltage at a frequency at which the capacitor's reactance is negligible, in a voltage divider configuration. It is easy to check ESR well enough for troubleshooting by using an improvised ESR meter comprising a simple square-wave generator and oscilloscope, or a sinewave generator of a few tens of kilohertz and an AC voltmeter, using a known good capacitor for comparison, or using a little mathematics.[2]
A professional ESR meter is more convenient for checking multiple capacitors in rapid succession on a crowded board. A standard measurement bridge, and many LCR and Q meters, can also measure ESR accurately, in addition to many other circuit parameters. The dedicated ESR meter is a relatively inexpensive special-purpose instrument of modest accuracy, used mainly to identify capacitors with unacceptably large ESR and sometimes to measure other low resistances; measurements of other parameters cannot be made.
Principles of ESR meter operation
Most ESR meters work by discharging a real electrolytic capacitor (essentially equivalent to a perfect capacitor in series with an unwanted resistance, the ESR) and passing an electric current through it for a short time, too short for it to charge appreciably. This will produce a voltage across the device equal to the product of the current and the ESR plus a negligible contribution from a small charge in the capacitor; this voltage is measured and its value divided by the current (i.e., the ESR) shown in ohms or milliohms on a digital display or by the position of a pointer on a scale. The process is repeated tens or hundreds of thousands of times a second.
Alternatively an alternating current at a frequency high enough that the capacitor's reactance is much less than the ESR can be used. Circuit parameters are usually chosen to give meaningful results for capacitance from about one microfarad up, a range that covers typical aluminium capacitors whose ESR tends to become unacceptably high.
Interpretation of readings
The ESR considered acceptable depends upon capacitance (larger capacitors usually have lower ESR), and may be read from a table of "typical" values, or compared with a new component. In principle, the manufacturer's upper limit specification for ESR can be looked up in a datasheet, but this is usually unnecessary. When a capacitor whose ESR is critical degrades, power dissipation through the higher ESR usually causes a rapid and large runaway increase, so go/no-go measurement is usually good enough as the ESR rapidly moves from a clearly acceptable to a clearly unacceptable level; an ESR of over a few ohms (less for a large capacitor) is unacceptable.
In a practical circuit, the ESR will be much lower than any other resistance in parallel with the capacitor, so it is not necessary to disconnect the component, and an in-circuit measurement can be made. Practical ESR meters use a voltage too low to switch on any semiconductor junctions that may be present in the circuit, which might present a low "on" impedance that would interfere with measurements.
Limitations
- An ESR meter does not measure the capacitance of a capacitor; the capacitor must be disconnected from the circuit and measured with a capacitance meter (or a multimeter with this capability). Excessive ESR is far more likely to be an identified problem with aluminium electrolytics rather than out-of-tolerance capacitance, which is rare in capacitors with acceptable ESR.
- A faulty short-circuited capacitor will incorrectly be identified by an ESR meter as having ideally low ESR, but an ohmmeter or multimeter can easily detect this case, which is much rarer in practice than high ESR. It is possible to connect the test probes to an ESR meter and ohmmeter in parallel to check for both shorts and ESR in one operation; some meters both measure ESR and detect short-circuits.
- ESR may depend upon operating conditions (mainly applied voltage, temperature); a capacitor which has excessive ESR at operating temperature and voltage may test as good if measured cold and unpowered. Some circuit faults due to such intermittent capacitors can be identified by using freeze spray; if cooling the capacitor restores correct operation, it is faulty.
- An ESR meter may be damaged by connection to a capacitor with significant voltage across it, either because of residual stored charge or in a live circuit. Protective diodes across the input will minimise this risk, but then the meter can no longer be used to measure battery internal resistance.
- When an ESR meter is used as a milliohmmeter, any significant inductance present between the test probes will make measurements meaningless. For example, an ESR meter is unsuitable for measuring the resistance of transformer windings because of their inductive characteristics. This effect is significant enough that test probes with coiled cords should not be used due to their inductance.
Other uses of ESR meters
An ESR meter is more accurately described as a pulsed or high-frequency AC milliohmmeter (depending upon type), and it can be used to measure any low resistance. Depending upon the exact circuit used, it may also be used to measure the internal resistance of batteries (many batteries end their useful life largely due to increased internal resistance, rather than low EMF. However, an ESR meter with back-to-back protective diodes across its input cannot be used to measure batteries), contact resistance of switches, the resistance of sections of printed circuit (PCB) track, etc.
While there are specialised instruments to detect short-circuits between adjacent PCB tracks, an ESR meter is useful because it can measure low resistances while injecting a voltage too low to confuse readings by switching on semiconductor junctions in the circuit. An ESR meter can be used to find short-circuits, even finding which of a group of capacitors or transistors connected in parallel by printed circuit tracks or wires is short-circuited. Many conventional ohmmeters and multimeters are not usable for very low resistances, and those that are often use too high a voltage, risking damage to the circuit being tested.
Tweezer probes are useful when test points are closely spaced, such as in equipment made with surface mount technology. The tweezer probes can be held in one hand, leaving the other hand free to steady or manipulate the equipment being tested.
See also
References
- ↑ Example of high-ESR capacitors causing voltages to rise in a circuit and destroy components. High ESR capacitors cause "5V dropping quite low and causing every other voltage to go sky high (and doing things like frying the HDD with upwards of 15V rather than 12V, and frying the tuning agc transistor with upwards of 36V instead of 30V)."
- ↑ Stephen M. Powell (2000). "99 cent ESR test adapter". Retrieved 2012-03-10.