Cyclone Mark V Engine

Cross Section of Cyclone Mark V Engine.

The Cyclone Mark V Engine is a steam engine in which the engine, steam generator, condenser and feed pump are integrated into a single compact unit. The company Cyclone Power Technologies of Pampano Beach, Florida was founded by inventor Harry Schoell to develop and market this engine. The Cyclone Mark V Engine is a six cylinder radial uniflow engine of two inch bore and two inch stroke. Pistons are single acting. The engine is claimed to produce 100 hp at 3600 rpm using steam at 3200 psi and 1200 °F.[1]

Timeline

Date Event
Sep 13, 2005 Harry Schoell files for U.S. Patent "Heat regenerative engine"[2] on what will become known as the Cyclone Mark V Engine.
April 2008 Popular Science Magazine named the cyclone engine Invention of The Year.[3] No engine had yet been built.
July 30, 2009 First two Mark V engines are sold to customer Phoenix Power Group LLC of Tennessee with a quoted delivery time of six months.[4] The contract required that "The Mark V engine shall produce approximately 92hp" and that "The final working prototype engine will have been thoroughly tested by continuously running the engine at a minimum of ¾ power for 7 consecutive days". The contract contained a late delivery penalty clause of $25,000 per month if engines were not delivered within nine months.
December 9, 2009 Cyclone Power Technologies promises a high performance Mark V engine[5] to Chuk Williams who was building a race car to break the land speed record for steam powered cars.[6]
December 11, 2009 A license is provided to Great Wall Alternative Power Systems Ltd, to produce Mark V engines for the China market. Technology was to be transferred "Upon the completion by Cyclone Power Technologies of its initial pre-production prototype Mark V engine in the United States, anticipated to be in mid to late 2010".[7]
October 18, 2010 Contract with Phoenix Power Group amended to substitute the delivery of two "WHE-25" (a small, simple steam engine) for the two Mark V engines in the original contract. However, the contract continues to state "Cyclone continues to use its best efforts to deliver two Mark V working prototype engines to Phoenix as soon as possible."[8]
April, 2011 The Raytheon company orders "multiple" Mark V engines.[9] Two engines were delivered to Raytheon in June 2012, although the delivered engines were "MantaRay 36" engines rather than Mark Vs.[10] The MantaRay engine did not have the burner, steam generator, condenser or combustion air preheaters of the Mark V engine.[11] There has been no news of these engines since the announcement of that delivery.
May, 2011 Cyclone Power Technologies builds a speedboat, the 'GG Mom', to break the water speed record for steam powered boats using the Mark V engine.[12] Although they state record attempts will be made that summer, the boat never appears to have been run.
September 12, 2011 The Combilift corporation in Ireland orders two Mark V engines. The contract specifies the engines will be "Run at Cyclone for a minimum of 50 hours prior to delivery to Combilift".[13] Delivery was to be in July, 2012.[14]
March 23, 2012 After numerous delays in the promised delivery of the Mark V engine for the land speed car, Chuk Williams announces the collaboration with Cyclone has ended.[15] Chuk obtains a steam engine and runs his car on the Bonneville Salt Flats in October, 2012[16]
April 2012 The contracted engines were not yet delivered to Phoenix Power group and "As of April 2012, the maximum $400,000 contracted penalty has been provided" for the late delivery.[17]
January 2, 2013 James Landon, CEO of Cyclone Power Technologies issues Letter to Shareholders and states: "To assist us in moving this project towards completion, we have recruited contractors with expertise in certain areas such as condensing systems. We are confident that we can start delivery of engines to our customer in the first half of 2013.[18]
February 2013 James Landon resigns as CEO and Director of Cyclone Power Technologies.[19] There is no further mention of contractors assisting in overcoming development problems with the Mark V engine.
September 2013 Great Wall Alternative Power Systems terminates Mark V engine license agreement with Cyclone Power Technologies.[20]
September 30, 2013 Contract with Phoenix Power Group amended to say "No other engines including the Mark V engines, other than as specifically stated herein, are required to be delivered", ending the order from Phoenix for Mark V engines.[21]
January 2, 2015 Cyclone Power Technologies reports "Our R&D team is moving towards completion of the Mark 5 project in Quarter 1 of 2015. These engines are to be delivered to Combilift for use as a clean-burning power supply in material lift equipment."[22]
February 23, 2015 Cyclone Power Technologies posts a video[23] of the Mark V engine undergoing testing. This engine differs considerably from previous descriptions of the Mark V. In particular:
  • There is a large automotive radiator and fan mounted externally to the engine acting as a condenser rather than the integral condenser that was the subject of US patent 7798204.[24]
  • There is no preheating of the combustion air. (See Schoell Cycle below.)
  • The admission valve system has changed from a cam and linkage operated poppet valve on each cylinder head to a central rotary valve. The cam and linkage valve control mechanism was the subject of US patents 7730873[25] and 7784280[26]

This version of the engine is not protected by the basic Cyclone Power Technologies engine patents US 7856822[27] and 7080512[28] (as well a variety of similar patents in other countries) because the patents only cover an engine with an integral condenser and that preheats combustion air. The version of the Mark V engine in this video does not have these features.

Functional Description

The Cyclone Engine is built of three major components, the Steam Generator, Piston Block, and Condenser. The working fluid, deionized water, travels continuously through these three components. Beginning in the steam generator, moving into the pistons, then to the condenser, and finally pumped back into the steam generator.[29]

Steam Generator

Steam Generator has three basic components: a coil of water tubes, surrounded by a series of burner assemblies, and covered with an insulated shroud. Each burner assembly consists of an air blower, which blows pre-heated air into the combustion chamber, a fuel atomizer, and an igniter.[30] The blower and atomizer are arranged so that the flame front is tangential to the water-tube coils.[30] Cyclone Power Technologies claims this arrangement allows the heavier particles in the fuel to circle the outside of the chamber until they are completely burned up, allowing for much cleaner, complete combustion of fuel, and resulting in cleaner emissions.[31] However, they have not performed any testing to verify this theory.[32]

The small size of the water tubes allows for much higher pressures than those of larger boilers, because of this, the water is not allowed to boil. Instead, it is allowed to reach supercritical temperature of up to 1200 °F.[31]

Piston Assembly

The piston assembly is an even number of pistons arranged radially around a single crankshaft. The pistons are attached to the crankshaft via a special "spider" bearing. This bearing consists of several small journal bearings attached to a disk which has a larger crankshaft journal bearing in the center. Each piston has one head admission valve. This valve is actuated by a variable cam on the crankshaft, and allows for the entrance of supercritical water into the cylinder. As the supercritical water enters the cylinder it flashes into steam and pushes the piston inward, thus rotating the crankshaft.

As the piston is pushed inward, it uncovers exhaust ports in the cylinder wall. The supercritical water has now given up enough energy through expansion that it is in a vapor state. This exhaust vapor passes out of the exhaust ports in the cylinder wall and across regenerative heating coils, which are wrapped around the cylinder. The heat from the exhaust vapor is used to preheat the water in these tubes before it enters the steam generator. The vapor then passes into the condenser.

Condenser

The condenser is a stack of interleaved circular plates, with an open core containing an impeller and a condensate sump underneath it. The exhaust vapor enters the top of the condenser from the piston block and is forced by the impeller onto the sides of the condenser and into the leaves of the circular plates. On the outside of the plates, a blower circulates air around the interleaved plates. This effectively condenses the exhaust vapor, which falls into the condensate sump at the bottom of the engine. A high pressure pump then pumps the condensate out of the sump, through the regenerative heating coils around the cylinder, and back into the steam generator.[33]

Schoell Cycle

Physical layout of the four main devices used in the Rankine cycle

"Schoell Cycle" is the name given by inventor Harry Schoell to his implementation of the Rankine cycle. The primary patent for the engine calls it a "Heat regenerative engine"[34]

In the Rankine cycle, water is pumped to high pressure, heated to produce steam, expanded in an engine producing mechanical work then heat is removed to condense the exhaust steam back into liquid water.

In the "Schoell Cycle", combustion air is first heated by passing it through the condenser, then heated further by passing it through a heat exchanger to absorb heat from the exhaust gasses.[34] This improves engine efficiency as less fuel needs to be burned to heat the combustion gasses to a given temperature. This technology has been extensively used in industrial furnaces and powerplants where it is known as an air preheater or APH.

A feedwater heater is placed around each cylinder where the exhaust steam exits. This transfers some heat to the water before it enters the steam generator, further reducing the amount of fuel necessary.

Although the Schoell patent is titled "Heat regenerative engine", it does not use the regenerative Rankine cycle nor does it use a regenerative heat exchanger.

Water Lubrication

The Mark V engine's design requires the use of water to lubricate the moving parts for two reasons:

  1. Exhaust steam goes into the engine crankcase. Any oil used to lubricate crankshaft and connecting rod bearings would soon form an emulsion of oil and water that would have very poor lubricating properties.
  2. Because of the integrated form of the Mark V and its small water capacity, any oil that enters the water will not leave the water while the engine is running. This oil will then coat and foul the inner surfaces of the condenser and steam generator, greatly reducing their performance. A non-integrated steam power system might have, for instance, a large water tank that will give oil time to separate from the water, or dedicated devices to separate oil from water.

Journal bearings on the crankshaft and connecting rods and the pistons sliding in their cylinders operate in the hydrodynamic lubrication regime. The carrying capacity of a journal bearing is a direct function of the dynamic viscosity of the lubricating fluid. Water at 20 °C has a viscosity of 0.001002 Pa·s, while a typical motor oil could have a viscosity of about 0.250 Pa·s.[35] Thus, water is about 250 times less effective of a lubricant than oil.

Cyclone Power Technologies had contracted with the Ohio State University Center for Automotive Research (OSU-CAR) for engineering analysis. A March 8, 2014 presentation [36] by OSU-CAR described the engine bearings as a "critical path issue" and stated:

  • "Little or no data exists outside Cyclone’s own experience for the use of water lubrication for either ball bearings or roller bearings in our environment and under our loadings. Calculated life using just the bearing load and the scaling factors for the viscosity of the lubricant indicate that very high ratio of load capacity to applied load is required."
  • "Minimal data exists for the use of water lubricated polymer journal bearings in our environment and under our loadings. Factors of a 4:1 increase in life have been shown with submerged operation, but little long term wear data is available with pressurized water lubrication."

The contract between Cyclone Power Technologies and Phoenix Power Group for the lower output WHE steam engine[21] states that Phoenix Power Group will make a $150,000 progress payment "Upon the completion of 200 hours of durability testing of WHE version 5.0 as conducted and/or overseen by OSU. The durability testing shall consist of the WHE engine operating, without failure, and producing 10hp to 20hp". As of February 28, 2015 there has been no indication they have made a water lubricated engine pass this 200 hour endurance test.

Measured Engine Performance

Very little information has been released by Cyclone Power Technologies on actual measured performance of the Mark V. The most detailed account comes from their Facebook page:[37]

July 15, 2013 ·

GREAT NEWS for the Cyclone Mark V Engine

As of today! Dyno testing has recorded 100HP and 1000 ft-lb of torque.

No other information such as engine configuration, test conditions, measurements taken, or duration of test has been reported.

Criticisms

Claims made for the Cyclone Mark V Engine include:

It's Clean: One promotional video claimed that exhaust leaving the engine would be cleaner than the air entering the engine: "The Cyclone will effectively act as an air scrubber that will help clean the air that we breath as it runs."[38] However, in the 2013 Annual Report, they state: "We have not yet performed this testing on our engines to meet any existing emission standards of the EPA and CARB."[32] No source has been provided to support their claim of low or no exhaust emissions.

It's Highly Efficient: Cyclone Power Technologies claims the Mark V engine has a thermal efficiency of 33%[39] The source of this efficiency figure is a calculation[40] based on a large number of assumed values. For instance, engine power output and fuel input values are both assumed. These give an estimated thermal efficiency of 23.2%. It is then assumed (without supporting calculations) that the heating of the combustion air improves overall engine efficiency by 4.05% and feedwater heating improves overall engine efficiency by a further 4.32%, bringing the total estimated engine thermal efficiency to 31.57%.

Portrayal of Mock-ups as Working Engines: A number of non-functional mock-ups of the Cyclone Mark V engine and larger and smaller variants have been built by Cyclone Power Technologies as promotional displays. The fact that they are not working engines, however, is often omitted. For instance, from various promotional videos:

In none of the videos does Harry Schoell state that the engines he points to are non-functional mock-ups, nor does he say any claims of performance are predictions and are not based on any actual measurements.

Applications

As of February 13, 2016 no Mark V engines had been delivered to any customers or publicly demonstrated running. Proposed applications included:

However, none of these proposals have been known to be implemented.

Variants

While the Mark V engine is the basic engine described in Cyclone Power Technologies' patents, a number of smaller and larger variants have been announced at different times.

Model Size Announced Details
Mark IV ~4 hp July 10, 2004[48]
  • Possibly the first test engine.
  • None known to have been sold, or demonstrated publicly.
Mark II 18HP October 12, 2004[49]
  • Applications described as "Portable & aux.power, light equipment"
  • Witnessed running March 4, 2005 and a 15 second video was made.[50]
  • None known to have been sold.
Mark VI 330 Hp Aug. 22, 2007[51]
  • Applications described as "Heavy transport, powerplant, heavy equipment"
  • Displayed at the 2007 SAE Commercial Vehicle Convention "Cyclone will display at this premier industry event its 100 HP Automotive Engine and its 330 HP Truck Engine, which will be installed in a full truck chassis for the first time." However, both engines were non-functional display mockups.
  • No working version of the Mark VI has been known to have been built.
Lawn Mower 5HP November 26, 2007[52]
  • Engine technology licensed to Revgine Inc. of Rochester, New York.
  • "Revgine has been granted the right to develop, manufacture and sell engines utilizing Cyclone's patented technology for use in lawn and garden equipment, such as lawn mowers, weed eaters, leaf blowers, snow blowers and chain saws."[52]
  • By April 2010, Cyclone Power Technologies announced "We have temporarily put on-hold the lawn mower project under our license with Revgine Inc."[53]
  • Although a non-functional display mockup was produced, no working engine is known to have been built.
Genie 80W September 3, 2008[54]
  • Applications described as "Portable power, battery charge-military"
  • Design was "was originally commissioned in May 2008 by APS (Advent Power Systems Inc.) and its client, MEO Products Ltd, a defense industry supplier based in the UK."[55]
  • "The company expects to deliver these beta prototype engines by the middle of 2009".[55] Four engines were ordered.
  • In May 2013 Cyclone Power Technologies reported "Cyclone's interest in micro-sized power units began several years ago with its 100W "Genie" concept, which was put on-hold pending additional funding and strategic partners."[56]
  • Although a non-functional display mockup was produced, no working engine is known to have been built.
WHE (Waste Heat Engine) 16-100HP Mar 31, 2008[57]
  • Applications described as "Waste heat recovery, Biomass-to-power"
  • Described as "a lower-pressure, lower-temperature off-shoot of the Cyclone Engine"
  • See main article Cyclone Waste Heat Engine
Solar I 5–15HP May 5, 2009[58]
  • Engine technology licensed to Renovalia Energy, S.A., based in Madrid, Spain for use in concentrating solar collectors.
  • The May 2009 announcement stated "the engine, called Cyclone Solar I, which could be deployed worldwide with their solar stations within a year."
  • On November 8, 2011 Cyclone Power Technologies delivered "prototype design plans" which satisfied the terms of the license.[59]
  • It is not clear if this engine design has been built.
S-2 10 kW August 2011
  • Cyclone Power Technologies and their licensee Advent Power Systems won a $1.4 million contract from U.S. Army / TACOM (Tank Automotive Command) to develop a compact 10 kW generator set: "The first prototype engine systems are scheduled to be developed, tested and delivered within 12 months."[60]
  • Cyclone Power Technologies announced delivery of one engine in May 2014.[61]
  • No details of acceptance criteria or engine performance have been given.[62]
Mark III ? Hp November 3, 2014[63]
  • Frankie Fruge, President of Cyclone announced "This is just the first part of a working relationship with Republic Energy with plans of integrating our Mark 3 engines into the system." No details of the engine have been given.
Mark I 5 Hp November 7, 2014[64]
  • Small, general purpose engine, configuration and details unknown.
  • Cyclone Power Technologies announced "that HyPex Inc. is manufacturing a pre-production of 10 Mark I engines to test performance and quality control before going into engine production on a larger scale."
  • On February 24, 2015, "Cyclone has just received the pre-production parts for 10 Mark 1 Engines and they are in the process of being assembled."[65]

References

  1. Fact sheet "Cyclone Engine Mark V Specifications". Retrieved from http://www.cyclonepower.com/PDF/MarkV_Spec_Sheet.pdf
  2. http://www.google.com/patents/US7080512
  3. Voelcker, John. (April 13, 2008) Steam Under The Hood. Popular Science Magazine. Retrieved from http://www.popsci.com/scitech/article/2008-05/steam-under-hood
  4. Systems Application License Agreement, filed as Exhibit 10.8 with the Securities and Exchange Commission. Retrieved from https://www.sec.gov/Archives/edgar/data/1442711/000139843211000685/ex10-8.htm
  5. Press Release "Cyclone Power Technologies to Build Engine For Steam Car Land Speed Record Attempt". Retrieved from http://www.cyclonepower.com/press/12-09-09.pdf
  6. 1 2 Steam Speed America. Retrieved from http://www.steamspeedamerica.com/
  7. Technology License Agreement, filed as Exhibit 10.9 with the Securities and Exchange Commission. Retrieved from https://www.sec.gov/Archives/edgar/data/1442711/000139843211000685/ex10-9.htm
  8. Amendment #2 to Systems Application License Agreement, filed as Exhibit 10.8.2 with the Securities and Exchange Commission. Retrieved from https://www.sec.gov/Archives/edgar/data/1442711/000139843211000685/ex10-82.htm
  9. Cyclone Power Technologies 2010, published April 22, 2011, page 26. Retrieved from http://www.otcmarkets.com/financialReportViewer?symbol=CYPW&id=48264
  10. Press release. "Cyclone Power Technologies Completes Engine Delivery". Bloomberg. Retrieved 5 March 2015.
  11. As can be seen in video: "Cyclone Power Technologies- MR-36 Performance Testing". Retrieved from https://www.youtube.com/watch?v=X9AJJC4TtSI
  12. 1 2 Article "Steam on the Water", Southern Boating magazine, May 2011. Retrieved from http://www.cyclonepower.com/PDF/SB0511%20EngRoom%203.pdf
  13. Systems Application License Agreement, filed as Exhibit 10.15 with the Securities and Exchange Commission. Retrieved from https://www.sec.gov/Archives/edgar/data/1442711/000139843211000847/ex10-15.htm
  14. Press release "Global Lift Equipment Manufacturer Signs Key License Agreement with Cyclone Power Technologies", September 14, 2011. Retrieved from http://www.bloomberg.com/apps/news?pid=newsarchive&sid=a7B0yFfWT9ZY
  15. Post to Steam Automobile Club of America forum. Retrieved from http://www.steamautomobile.com/ForuM/read.php?1,14474,19822#msg-19822
  16. Video of Chuk Williams car running on the Bonneville Salt Flats. Retrieved from https://www.youtube.com/watch?v=F3eatDRIV-s
  17. Note 15 in the Quarterly Report for the quarterly period ended March 31, 2012, filed with the Securities and Exchange Commission. Retrieved from https://www.sec.gov/Archives/edgar/data/1442711/000139843212000427/i11835.htm
  18. Press release "Cyclone Power Technologies Releases Year End Progress Letter to Shareholders." Retrieved from http://www.marketwired.com/press-release/cyclone-power-technologies-releases-year-end-progress-letter-to-shareholders-otcqb-cypw-1741762.htm
  19. James C. Landon LinkedIn page. Retrieved from https://www.linkedin.com/pub/james-c-landon/5/4b5/706
  20. Page 19 in the Quarterly Report for the quarterly period ended September 30, 2013, filed with the Securities and Exchange Commission. Retrieved from https://www.sec.gov/Archives/edgar/data/1442711/000139843213000757/cypw20130930_10q.htm
  21. 1 2 Amended and Restated Systems Application License Agreement, filed as Exhibit 10.25 with the Securities and Exchange Commission. https://www.sec.gov/Archives/edgar/data/1442711/000139843213000687/ex10-25.htm
  22. Page 19 in the Quarterly Report for the quarterly period ended September 30, 2014, filed with the Securities and Exchange Commission. Retrieved from https://www.sec.gov/Archives/edgar/data/1442711/000139843215000004/cypw20140930_10q.htm
  23. Retrieved from https://www.youtube.com/watch?v=gF066FmT5p4&feature=youtu.be
  24. US patent 7798204 "Centrifugal condenser" Retrieved from https://www.google.com/patents/US7798204
  25. US patent 7730873 "Valve controlled throttle mechanism in a heat regenerative engine" Retrieved from https://www.google.com/patents/US7730873
  26. US patent 7784280 "Engine reversing and timing control mechanism in a heat regenerative engine" Retrieved from https://www.google.com/patents/US7784280
  27. US patent 7856822 "Heat regenerative engine" Retrieved from https://www.google.com/patents/US7856822
  28. US patent 7080512 "Heat regenerative engine" Retrieved from https://www.google.com/patents/US7080512
  29. (2012, April 5). How It Works. Retrieved from http://www.cyclonepower.com/works.html
  30. 1 2 Schoell, Harry. (2007). US Patent No. 7,407,382: Steam Generator in a Heat Regenerative Engine. Washington, DC: U.S. Patent and Trademark Office.
  31. 1 2 Allan, Sterling D. (2007, March 17). Harry Schoell, Cyclone Technologies. "Schoell cycle engine is a cross between a Rankine, Diesel and Carnot cycle engine. Compact, scalable technology is in process of being taken to market." // Free Energy Now Radio Show. Recording retrieved from http://pesn.com/Radio/Free_Energy_Now/archive/2007.htm
  32. 1 2 Page 7 of Cyclone Power Technology Annual Report. Retrieved from https://www.sec.gov/Archives/edgar/data/1442711/000139843214000164/cypw20131231_10k.htm
  33. Schoell, Harry. (2007). US Patent No. 7,798,204 B2: Cenrifugal Condenser. Washington, DC: U.S. Patent and Trademark Office.
  34. 1 2 U.S. Patent 7,080,512. Retrieved from http://www.google.com/patents/US7080512
  35. Serway, Raymond A. (1996). Physics for Scientists & Engineers (4th ed.). Saunders College Publishing. ISBN 0-03-005932-1.
  36. ENGINEERING ANALYSIS OF CYCLONE POWER TECHNOLOGIES’ WASTE HEAT ENGINE. Retrieved from http://www.cyclonepower.com/2014/IAASP_Presentation_OSU-CAR_Cyclone_March-8-2014.pdf
  37. Cyclone Power Technologies Facebook entry, July 15, 2013. Retrieved from https://www.facebook.com/CyclonePowerTechnologies/posts/594415553923847:0
  38. Cyclone Power Technologies promotional video, statement at 2:49. Retrieved from https://www.youtube.com/watch?v=eFIbB97HcgY&list=PL_3nDAEol0ZirCv_H2pbKq_lxc3I9KG0J&index=1
  39. Butler, Greg, "'All fuel' engine opens way for bio-fuels on farm", SANTFA The Cutting Edge magazine, Autumn 2013 issue. Retrieved from http://www.santfa.com.au/wp-content/uploads/Santfa-TCE-Autumn-13-%E2%80%98All-fuel%E2%80%99-engine-opens-way-for-bio-fuels-on-farm.pdf
  40. "Cyclone Mark V Efficiency Calculations" Prepared By: Harry Schoell, Inventor. Retrieved from http://www.cyclonepower.com/PDF/Mark%20V%20Efficency%20Calculations.pdf
  41. Engineering TV interview with Harry Schoell, posted June 03, 2008. Retrieved from http://www.engineeringtv.com/video/Cyclone-External-Combustion-Eng
  42. Engineering TV second interview with Harry Schoell, posted June 03, 2008. Retrieved from http://www.engineeringtv.com/video/Cyclone-Waste-Heat-Engine
  43. Video in article Steam Under the Hood, Popular Science Magaine, Posted May 13, 2008. Retrieved from http://www.popsci.com/scitech/article/2008-05/steam-under-hood
  44. The Phoenix 40 Generator. Retrieved from http://phoenixpowergroup.com/phoenix-generators/p5s/
  45. Press release: "Cyclone-Williams Steam-Powered Speedster Races towards Starting Line for World Record Attempt". Retrieved from http://www.businesswire.com/news/home/20110125006433/en/Cyclone-Williams-Steam-Powered-Speedster-Races-Starting-Line-World#.VPxsYuF26zk
  46. Team Steam USA car webpage. Retrieved from http://www.uslandsteamrecord.com/
  47. Press release: "Cyclone Power Technologies Signs Letter of Intent with Leading Global Lift Equipment Manufacturer, Combilift". Retrieved from http://www.businesswire.com/news/home/20110627006035/en/Cyclone-Power-Technologies-Signs-Letter-Intent-Leading#.VLSd03t26zk
  48. Harry Schoell in discussion post at Steam Automobile Club of America, July 10, 2004. Retrieved from http://www.steamautomobile.com/ForuM/read.php?1,3347
  49. Harry Schoell in discussion post at Steam Automobile Club of America, October 12, 2004. Retrieved from http://www.steamautomobile.com/ForuM/read.php?1,3347
  50. George Nutz, "Mark II Cyclone Steam Plant". Retrieved from http://www.stanleysteamers.com/cyclone.htm
  51. Press release: "Cyclone Power Technologies to Showcase Two Clean Green Automotive Engines At SAE Convention". Retrieved from http://globenewswire.com/news-release/2007/08/22/364628/125391/en/Cyclone-Power-Technologies-to-Showcase-Two-Clean-Green-Automotive-Engines-At-SAE-Convention.html
  52. 1 2 Press release: "Cyclone Power Technologies Signs License to Manufacture Clean Green Lawn Equipment". Retrieved from http://www.marketwired.com/press-release/cyclone-power-technologies-signs-license-to-manufacture-clean-green-lawn-equipment-796389.htm
  53. Cyclone Power Technologies Files Audited Financials; Releases Progress Report to Shareholders, April 06, 2010. Retrieved from http://www.bloomberg.com/apps/news?pid=newsarchive&sid=acHhnTNt5dkc
  54. Press release: "Cyclone Power Technologies to Showcase Three Clean Green Engines at SAE Conference". Retrieved from http://www.bloomberg.com/apps/news?pid=newsarchive&sid=a9DhzlaFxl7A
  55. 1 2 Press release: "Military Licensee Purchases Man-Portable Beta Engines From Cyclone Power Technologies". Retrieved from http://www.marketwired.com/press-release/military-licensee-purchases-man-portable-beta-engines-from-cyclone-power-technologies-1247300.htm
  56. Press release: "Cyclone Power Technologies Signs MOU With McGill University to Advance Combustion Systems for Micro-Sized Power Units". Retrieved from http://www.macreportmedia.com/ViewSubmission.aspx?submissionRequest=23054
  57. Initial Company Information and Disclosure Statement, Mar 31, 2008. Retrieved from http://www.otcmarkets.com/financialReportViewer?symbol=CYPW&id=14839
  58. Press release: "Global Renewable Energy Leader Signs License with Cyclone Power Technologies for Solar Thermal Engines". Retrieved from http://www.businesswire.com/news/home/20090505005484/en/Global-Renewable-Energy-Leader-Signs-License-Cyclone#.VQjxAuF26zk
  59. Press release: "Cyclone Power Technologies Delivers Plans for Solar Engine to Renovalia Energy". Retrieved from http://www.businesswire.com/news/home/20111108005299/en/Cyclone-Power-Technologies-Delivers-Plans-Solar-Engine#.VQjyP-F26zk
  60. Press release: "Cyclone Power Technologies and Advent Power Systems Win $1.4 Million Development Contract from U.S. Army". Retrieved from http://www.reuters.com/article/2011/08/01/idUS141970+01-Aug-2011+BW20110801
  61. Press release: "Cyclone Power Technologies Delivers Engine in Full Satisfaction of U.S. Army / TARDEC Development Contract". Retrieved from http://finance.yahoo.com/news/cyclone-power-technologies-delivers-engine-123000596.html
  62. Karl A. Petersen, "Cyclone Genset Accepted by U S Army - TARDEC" Retrieved from http://www.cyclonepower.com/2014/Cyclone%20Genset%20Accepted%20by%20U%20S%20Army%20-%20TARDEC.pdf
  63. Press release: "Cyclone Power Technologies Receives Purchase Order for $135,000 to Provide a Hydrocarbon Extractor System". Retrieved from http://finance.yahoo.com/news/cyclone-power-technologies-receives-purchase-140000037.html
  64. Press release: "Cyclone Power Technologies Authorizes Pre-Production of Mark 1 Engines ". Retrieved from http://www.marketwired.com/press-release/cyclone-power-technologies-authorizes-pre-production-of-mark-1-engines-pinksheets-cypw-1965749.htm
  65. Press release: "Cyclone Power Technologies Inc. Progress Report". Retrieved from http://finance.yahoo.com/news/cyclone-power-technologies-inc-progress-140000034.html;_ylt=AwrBJSCbaAtVmnMAgOCTmYlQ

External links

This article is issued from Wikipedia - version of the Sunday, February 14, 2016. The text is available under the Creative Commons Attribution/Share Alike but additional terms may apply for the media files.