Chemiluminescence

Not to be confused with Fluorescence.
A chemoluminescent reaction in an erlenmeyer flask
Chemiluminescence after a reaction of hydrogen peroxide and luminol.

Chemiluminescence (sometimes "chemoluminescence") is the emission of light (luminescence), as the result of a chemical reaction. There may also be limited emission of heat. Given reactants A and B, with an excited intermediate ,

[A] + [B] → [] → [Products] + light

For example, if [A] is luminol and [B] is hydrogen peroxide in the presence of a suitable catalyst we have:

luminol + hydrogen peroxide → 3-APA[] → 3-APA + light

where:

The decay of this excited state[] to a lower energy level causes light emission. In theory, one photon of light should be given off for each molecule of reactant. This is equivalent to Avogadro's number of photons per mole of reactant. In actual practice, non-enzymatic reactions seldom exceed 1% QC, quantum efficiency.

In a chemical reaction, reactants collide to form a transition state, the enthalpic maximum in a reaction coordinate diagram, which proceeds to the product. Normally, reactants form products of lesser chemical energy. The difference in energy between reactants and products, represented as \Delta H_{rxn}, is turned into heat, physically realized as excitations in the vibrational state of the normal modes of the product. Since vibrational energy is generally much greater than the thermal agitation, it rapidly disperses in the solvent through molecular rotation. This is how exothermic reactions make their solutions hotter. In a chemiluminescent reaction, the direct product of the reaction is an excited electronic state. This state then decays into an electronic ground state and emits light through either an allowed transition (analogous to fluorescence) or a forbidden transition (analogous to phosphorescence), depending partly on the spin state of the electronic excited state formed.

Chemiluminescence differs from fluorescence or phosphorescence in that the electronic excited state is the product of a chemical reaction rather than of the absorption of a photon. It is the antithesis of a photochemical reaction, in which light is used to drive an endothermic chemical reaction. Here, light is generated from a chemically exothermic reaction.

A standard example of chemiluminescence in the laboratory setting is the luminol test. Here, blood is indicated by luminescence upon contact with iron in hemoglobin. When chemiluminescence takes place in living organisms, the phenomenon is called bioluminescence. A light stick emits light by chemiluminescence.

Liquid-phase reactions

luminol + H2O2 → 3-APA[] → 3-APA + light

Gas-phase reactions

Green and blue glowsticks.
NO+O3 → NO2[]+ O2
The activated NO2[] luminesces broadband visible to infrared light as it reverts to a lower energy state. A photomultiplier and associated electronics counts the photons that are proportional to the amount of NO present. To determine the amount of nitrogen dioxide, NO2, in a sample (containing no NO) it must first be converted to nitric oxide, NO, by passing the sample through a converter before the above ozone activation reaction is applied. The ozone reaction produces a photon count proportional to NO that is proportional to NO2 before it was converted to NO. In the case of a mixed sample that contains both NO and NO2, the above reaction yields the amount of NO and NO2 combined in the air sample, assuming that the sample is passed through the converter. If the mixed sample is not passed through the converter, the ozone reaction produces activated NO2[] only in proportion to the NO in the sample. The NO2 in the sample is not activated by the ozone reaction. Though unactivated NO2 is present with the activated NO2[], photons are emitted only by the activated species that is proportional to original NO. Final step: Subtract NO from (NO + NO2) to yield NO2[4]

Infrared chemiluminescence

In chemical kinetics, infrared chemiluminiscence (IRCL) refers to the emission of infrared photons from vibrationally excited product molecules immediately after their formation. The intensities of infrared emission lines from vibrationally excited molecules are used to measure the populations of vibrational states of product molecules.[5][6]

The observation of IRCL was developed as a kinetic technique by John Polanyi, who used it to study the attractive or repulsive nature of potential energy surface for gas-phase reactions. In general the IRCL is much more intense for reactions with an attractive surface, indicating that this type of surface leads to energy deposition in vibrational excitation. In contrast reactions with a repulsive potential energy surface lead to little IRCL, indicating that the energy is primarily deposited as translational energy.[7]

Enhanced chemiluminescence

Enhanced chemiluminescence is a common technique for a variety of detection assays in biology. A horseradish peroxidase enzyme (HRP) is tethered to an antibody that specifically recognizes the molecule of interest. This enzyme complex then catalyzes the conversion of the enhanced chemiluminescent substrate into a sensitized reagent in the vicinity of the molecule of interest, which on further oxidation by hydrogen peroxide, produces a triplet (excited) carbonyl, which emits light when it decays to the singlet carbonyl. Enhanced chemiluminescence allows detection of minute quantities of a biomolecule. Proteins can be detected down to femtomole quantities,[8] well below the detection limit for most assay systems.

Applications

Biological applications

Chemiluminescence has been applied by forensic scientists to solve crimes. In this case, they use luminol and hydrogen peroxide. The iron from the blood acts as a catalyst and reacts with the luminol and hydrogen peroxide to produce blue light for about 30 seconds. Because only a small amount of iron is required for chemiluminescence, trace amounts of blood are sufficient.

In biomedical research, the protein that gives fireflies their glow and its co-factor, luciferin, are used to produce red light through the consumption of ATP. This reaction is used in many applications, including the effectiveness of cancer drugs that choke off a tumor's blood supply. This form of bioluminescence imaging allows scientists to test drugs in the pre-clinical stages cheaply. Another protein, aequorin, found in certain jellyfish, which produces blue light in the presence of calcium). It can be used in molecular biology to assess calcium levels in cells. What these biological reactions have in common is their use of adenosine triphosphate (ATP) as an energy source. Though the structure of the molecules that produce luminescence is different for each species, they are given the generic name of luciferin. Firefly luciferin can be oxidized to produce an excited complex. Once it falls back down to a ground state a photon is released. It is very similar to the reaction with luminol.

Luciferase = Luciferin + ATP + O2 → Oxyluciferin + Light + AMP + PPi

Many organisms have evolved to produce light in a range of colors. At the molecular level, the difference in color arises from the degree of conjugation of the molecule, when an electron drops down from the excited state to the ground state. Deep sea organisms have evolved to produce light lure and catch prey, as camouflage or attract others. Some bacteria even use bioluminescence to communicate. The common colors for the light emitted by these animals are blue and green because they have shorter wavelength than red and can transmit more easily in water.

Chemiluminescence is different from fluorescence. Hence the application of fluorescent proteins such as Green fluorescent protein is not a biological application of chemiluminescence.

See also

References

  1. "Luminol chemistry laboratory demonstration". Retrieved 2006-03-29.
  2. "Investigating luminol" (PDF). Salters Advanced Chemistry. Retrieved 2006-03-29.
  3. Rauhut, Michael M. (1985), Chemiluminescence. In Grayson, Martin (Ed) (1985). Kirk-Othmer Concise Encyclopedia of Chemical Technology (3rd ed), pp 247 John Wiley and Sons. ISBN 0-471-51700-3
  4. Air Zoom | Glowing with Pride. Fannation.com. Retrieved on 2011-11-22.
  5. Atkins P. and de Paula J. Physical Chemistry (8th ed., W.H.Freeman 2006) p.886 ISBN 0-7167-8759-8
  6. Steinfeld J.I., Francisco J.S. and Hase W.L. Chemical Kinetics and Dynamics (2nd ed., Prentice-Hall 1998) p.263 ISBN 0-13-737123-3
  7. Atkins P. and de Paula J. p.889-890
  8. Enhanced CL review. Biocompare.com (2007-06-04). Retrieved on 2011-11-22.
  9. ECOPHYSICS CLD790SR2 NO/NO2 analyser
  10. Stella, P., Kortner, M., Ammann, C., Foken, T., Meixner, F. X., and Trebs, I.: Measurements of nitrogen oxides and ozone fluxes by eddy covariance at a meadow: evidence for an internal leaf resistance to NO2, Biogeosciences, 10, 5997-6017, doi:10.5194/bg-10-5997-2013, 2013.
  11. Tsokankunku, Anywhere: Fluxes of the NO-O3-NO2 triad above a spruce forest canopy in south-eastern Germany. Bayreuth , 2014 . - XII, 184 P. ( Doctoral thesis, 2014 , University of Bayreuth, Faculty of Biology, Chemistry and Earth Sciences)
  12. Kinn, John J "Chemiluminescent kite" U.S. Patent 4,715,564issued 12/29/1987
  13. Kuntzleman, Thomas Scott; Rohrer, Kristen; Schultz, Emeric (2012-06-12). "The Chemistry of Lightsticks: Demonstrations To Illustrate Chemical Processes". Journal of Chemical Education 89 (7): 910–916. doi:10.1021/ed200328d. ISSN 0021-9584.
  14. Chemiluminescence as a Combustion Diagnostic Venkata Nori and Jerry Seitzman - AIAA - 2008
This article is issued from Wikipedia - version of the Sunday, January 10, 2016. The text is available under the Creative Commons Attribution/Share Alike but additional terms may apply for the media files.