Asynchronous serial communication
Asynchronous serial communication is a form of serial communication in which the communicating endpoints' interfaces are not continuously synchronized by a common clock signal. Instead of a common synchronization signal, the data stream contains synchronization information in form of start and stop signals, before and after each unit of transmission, respectively. The start signal prepares the receiver for arrival of data and the stop signal resets its state to enable triggering of a new sequence.
A common kind of start-stop transmission is ASCII over RS-232, for example for use in teletypewriter operation.
Origin
Mechanical teleprinters using 5-bit codes (see Baudot code) typically used a stop period of 1.5 bit times.[1] Very early electromechanical teletypewriters (pre-1930) could demand 2 stop bits to allow mechanical impression without buffering. Hardware which does not support fractional stop bits can communicate with a device that uses 1.5 bit times if it is configured to send 2 stop bits when transmitting and requiring 1 stop bit when receiving.
The format is derived directly from the design of the teletypewriter, which was designed this way because the electromechanical technology of its day was not precise enough for synchronous operation: thus the systems needed to be re-synchronized at the start of each character. Having been re-synchronized, the technology of the day was good enough to preserve bit-sync for the remainder of the character. The stop bits gave the system time to recover before the next start bit. Early teleprinter systems used five data bits, typically with some variant of the Baudot code.
Very early experimental printing telegraph devices used only a start bit and required manual adjustment of the receiver mechanism speed to reliably decode characters. Automatic synchronization was required to keep the transmitting and receiving units "in step". This was finally achieved by Howard Krum, who patented the start-stop method of synchronization (US 1199011, granted September 19, 1916, then US 1286351, granted December 3, 1918). Shortly afterward a practical teleprinter was patented (US 1232045, granted July 3, 1917).
Operation
Before signalling will work, the sender and receiver must agree on the signalling parameters:
- Full or half-duplex operation
- The number of bits per character
- Endianness: the order in which the bits are sent
- The speed or bits per second of the line (often incorrectly referred to as the Baud rate). Some systems use automatic speed detection.
- Whether to use or not use parity
- Odd or even parity, if used
- The number of stop bits sent must be chosen (the number sent must be at least what the receiver needs)
- Mark and space symbols (current directions in early telegraphy, later voltage polarities in EIA RS-232 and so on, frequency shift polarities in frequency shift keying and so on)
Asynchronous start-stop signalling was widely used for dial-up modem access to time-sharing computers and BBS systems. These systems used either seven or eight data bits, transmitted least-significant bit first, in accordance with the ASCII standard.
Between computers, the most common configuration used was "8N1": eight bit characters, with one start bit, one stop bit, and no parity bit. Thus 10 Baud times are used to send a single character, and so dividing the signalling bit-rate by ten results in the overall transmission speed in characters per second.
Asynchronous start-stop is the physical layer used to connect computers to modems for many dial-up Internet access applications, using a data link framing protocol such as PPP to create packets made up out of asynchronous serial characters. The performance loss relative to synchronous access is negligible, as most modern modems will use a private synchronous protocol to send the data between themselves, and the asynchronous links at each end are operated faster than this data link, with flow control being used to throttle the data rate to prevent overrun.
See also
- Comparison of synchronous and asynchronous signalling
- Degree of start-stop distortion
- Synchronous serial communication
- Universal asynchronous receiver/transmitter
References
- ↑ Description, Typebar Page Printer (Model 15) (PDF). Bulletin No. 144. Chicago: Teletype Corporation. 1931. p. 11.Dead link: 2015-Oct-03
Further reading
- Nelson, R. A. and Lovitt, K. M. History of Teletypewriter Development (October 1963), Teletype Corporation, retrieved April 14, 2005
- Hobbs, Allan G. (1999) Five-unit codes, accessed 20 December 2007
External links
- Programming:Serial Data Communications at Wikibooks