1,2-Dichlorotetrafluoroethane
| |||
Names | |||
---|---|---|---|
IUPAC name
1,2-Dichlorotetrafluoroethane | |||
Other names
R-114, CFC-114, halon 242, cryofluorane, Freon 114, Genetron 114, Refrigerant 114 | |||
Identifiers | |||
76-14-2 | |||
ChEMBL | ChEMBL325436 | ||
ChemSpider | 6189 | ||
EC Number | 200-937-7 | ||
Jmol interactive 3D | Image | ||
UNII | 6B5VVT93AR | ||
| |||
Properties | |||
C2Cl2F4 | |||
Molar mass | 170.92 g/mol | ||
Appearance | colorless gas[1] | ||
Odor | faint, ether-like (high concentrations)[1] | ||
Density | 1.455 g/cm3 | ||
Melting point | −94 °C (−137 °F; 179 K) | ||
Boiling point | 3.5 °C (38.3 °F; 276.6 K) | ||
0.01%[1] | |||
Vapor pressure | 1.9 atm (21°C)[1] | ||
Hazards | |||
Main hazards | Ozone depletor | ||
Flash point | nonflammable [1] | ||
Lethal dose or concentration (LD, LC): | |||
LC50 (Median concentration) |
720,000 ppm (rat, 30 min) 700,000 ppm (mouse, 30 min) 750,000 ppm (rabbit, 30 min)[2] | ||
US health exposure limits (NIOSH): | |||
PEL (Permissible) |
TWA 1000 ppm (7000 mg/m3)[1] | ||
REL (Recommended) |
TWA 1000 ppm (7000 mg/m3)[1] | ||
IDLH (Immediate danger |
15000 ppm[1] | ||
Except where otherwise noted, data are given for materials in their standard state (at 25 °C [77 °F], 100 kPa). | |||
verify (what is ?) | |||
Infobox references | |||
1,2-Dichlorotetrafluoroethane, or R-114, also known as cryofluorane (INN), is a chlorofluorocarbon (CFC) with the molecular formula ClF2CCF2Cl. Its primary use has been as a refrigerant. It is a non-flammable gas with a sweetish, chloroform-like odor with the critical point occurring at 145.6 °C and 3.26 MPa. When pressurized or cooled, it is a colorless liquid. It is listed on the Intergovernmental Panel on Climate Change's list of ozone depleting chemicals, and is classified as a Montreal Protocol Class I, group 1 ozone depleting substance.[3]
When used as a refrigerant, R-114 is classified as a medium pressure refrigerant.
The US Navy uses R-114 in its centrifugal chillers in preference to R-11 to avoid air and moisture leakage into the system. While the evaporator of an R-11 charged chiller runs at a vacuum during operation, R-114 yields approximately 0 psig operating pressure in the evaporator.
References
- 1 2 3 4 5 6 7 8 "NIOSH Pocket Guide to Chemical Hazards #0201". National Institute for Occupational Safety and Health (NIOSH).
- ↑ "Dichlorotetrafluoroethane". Immediately Dangerous to Life and Health. National Institute for Occupational Safety and Health (NIOSH).
- ↑ Class I Ozone-depleting Substances, United States Environmental Protection Agency, retrieved May 11, 2012
External links
- Material Safety Data Sheet from Honeywell International Inc., dated 22 August 2007.
- CDC - NIOSH Pocket Guide to Chemical Hazards
|
|