Vena contracta
Vena contracta is the point in a fluid stream where the diameter of the stream is the least, and fluid velocity is at its maximum, such as in the case of a stream issuing out of a nozzle, (orifice). (Evangelista Torricelli, 1643). It is a place where the cross section area is minimum. The maximum contraction takes place at a section slightly downstream of the orifice, where the jet is more or less horizontal.
The effect is also observed in flow from a tank into a pipe, or a sudden contraction in pipe diameter. Streamlines will converge just downstream of the diameter change, and a region of separated flow occurs from the sharp corner of the diameter change and extends past the vena contracta.
Explanation
The reason for this phenomenon is that fluid streamlines cannot abruptly change direction. In the case of both the free jet and the sudden pipe diameter change, the streamlines are unable to closely follow the sharp angle in the pipe/tank wall. The converging streamlines follow a smooth path, which results in the narrowing of the jet (or primary pipe flow) observed.
Echocardiography
Measurement of the vena contracta is useful in echocardiography, where it describes the smallest area of the blood flow jet as it exits a heart valve. This corresponds to the Effective Orifice Area calculated for heart valves using the continuity equation.
Shotguns
Vena Contracta was also a term used by several English shotgun builders of the 19th and 20th Century. The gun barrels of sporting shotguns tapered very heavily from the breech to the muzzle. Thus a gun with a 12 bore breech would have a 20 bore muzzle. The idea was to retain the advantages a heavy-hitting large bore shotgun while retaining the lesser recoil and easy maneuverability of a small bore. Several leading firms built this type of gun but it proved unpopular and most were returned to the manufacturers for large bore barrels. To most shooters perhaps the idea of placing a 12 bore cartridge into a 20 bore barrel was too "explosive". Complete functioning example are now rare though they are still are not highly sought after. See lot 1700 at the Holt gun auction in London, June 2014.
Coefficient of contraction
It is the ratio between the area of the jet at the vena contracta to the area of the orifice.
Cc = Area at vena contracta/ Area of orifice
The typical value may be taken as 0.64 for a sharp orifice (concentric with the flow channel). The smaller the value, the more effect the vena contracta has.