Ives–Stilwell experiment

Ives–Stilwell experiment (1938). "Canal rays" (a mixture of mostly H2+ and H3+ ions) were accelerated through perforated plates charged from 6,788 to 18,350 volts. The beam and its reflected image were simultaneously observed with the aid of a concave mirror offset 7° from the beam.[1] (The offset in this illustration is exaggerated.)

The Ives–Stilwell experiment tested the contribution of relativistic time dilation to the Doppler shift of light.[1][2] The result was in agreement with the formula for the transverse Doppler effect, and was the first direct, quantitative confirmation of the time dilation factor. Since then, many Ives–Stilwell type experiments have been performed with increased precision. Together with the Michelson–Morley and Kennedy–Thorndike experiments, it forms one of the fundamental tests of special relativity theory.[3] Other tests confirming the relativistic Doppler effect, are the Mössbauer rotor experiment and modern Ives–Stilwell experiments. For other time dilation experiments, see Time dilation of moving particles. For general overview, see Tests of special relativity.

Both time dilation and the relativistic Doppler effect were predicted by Albert Einstein in his seminal 1905 paper.[4] Einstein subsequently (1907) suggested an experiment based on the measurement of the relative frequencies of light perceived as arriving from a light source in motion with respect to the observer, and he calculated the additional Doppler shift due to time dilation.[5] This effect was later called "transverse Doppler effect" (TDE), since such experiments were initially imagined to be conducted at right angles with respect to the moving source, in order to avoid the influence of the longitudinal Doppler shift. Eventually, Herbert E. Ives and G. R. Stilwell (referring to time dilation as following from the theory of Lorentz and Larmor) gave up the idea of measuring this effect at right angles. They used rays in longitudinal direction and found a way to separate the much smaller TDE from the much bigger longitudinal Doppler effect. The experiment was performed in 1938[1] and it was reprised several times (see, e.g.[2]). Similar experiments were conducted several times with increased precision, by Otting (1939),[6] Mandelberg et al. (1962),[7] Hasselkamp et al. (1979),[8]

Experiments with "canal rays"

The experiment of 1938

Ives remarked that it is nearly impossible to measure the transverse Doppler effect with respect to light rays emitted by canal rays at right angles to the direction of motion of the canal rays (as it was considered earlier by Einstein), because the influence of the longitudinal effect can hardly be excluded. Therefore he developed a method, to observe the effect in the longitudinal direction of the canal rays' motion. If it is assumed that the speed of light is fixed with respect to the observer ("classical theory"), then the forward and rearward Doppler-shifted frequencies seen on a moving object will be

\frac{f_{o}}{f_{s}}=\frac{c}{c\pm v},

where v is recession velocity. Under special relativity, the two frequencies will also include an additional Lorentz factor redshift correction represented by the TDE formula:

\frac{f_o}{f_s}=\sqrt{1-\frac{v^2}{c^2}}

When we invert these relationships so that they relate to wavelengths rather than frequencies, "classical theory" predicts redshifted and blueshifted wavelength values of 1 + v/c and 1 − v/c, so if all three wavelengths (redshifted, blueshifted and original) are marked on a linear scale, according to classical theory the three marks should be perfectly evenly spaced.

 |\cdot\cdot\cdot\cdot\cdot|\cdot\cdot\cdot\cdot\cdot| \,

But if the light is shifted by special relativity's predictions, the additional Lorentz offset means that the two outer marks will be offset in the same direction with respect to the central mark.

 |\cdot\cdot\cdot\cdot|\cdot\cdot\cdot\cdot\cdot\cdot| \,

Ives and Stilwell found that there was a significant offset of the centre of gravity of the three marks, and therefore the Doppler relationship was not that of "classical theory".

Why it is difficult to measure the transverse Doppler effect accurately using a transverse beam. The illustration shows the results of attempting to measure the 4861 ångström line emitted by a beam of "canal rays" as they recombine with electrons stripped from the dilute hydrogen gas used to fill the canal ray tube. With v = 0.005 c, the predicted result of the TDE would be a 4861.06 ångström line. On the left, conventional Doppler shift results in broadening the emission line to such an extent that the TDE cannot be observed. In the middle, we see that even if one narrows one's view to the exact center of the beam, very small deviations of the beam from an exact right angle introduce shifts comparable to the predicted effect. Ives and Stilwell used a concave mirror that allowed them to simultaneously observe a nearly longitudinal direct beam (blue) and its reflected image (red). Spectroscopically, three lines would be observed: An undisplaced emission line, and blueshifted and redshifted lines. The average of the redshifted and blueshifted lines was compared with the undisplaced line.

This approach had two main advantages:

  1. It didn't require a commitment to an exact value for the velocity involved (which might have been theory-dependent).
  2. It didn't require an understanding or interpretation of angular aberration effects, as might have been required for the analysis of a "true" transverse test. A "true transverse test" was run almost 40 years later by Hasselkamp in 1979.[8]

The experiment of 1941

In the 1938 experiment, the maximum TDE was limited to 0.047 Å. The chief difficulty that Ives and Stilwell encountered in attempts to achieve larger shifts was that when they raised the electric potential between the accelerating electrodes to above 20,000 volts, breakdown and sparking would occur that could lead to destruction of the tube.

This difficulty was overcome by using multiple electrodes. Using a four electrode version of the canal ray tube with three gaps, a total potential difference of 43,000 volts could be achieved. A voltage drop of 5,000 volts was used across the first gap, while the remaining voltage drop was distributed between the second and third gaps. With this tube, a highest shift of 0.11 Å was achieved for H2+ ions.

Other aspects of the experiment were also improved. Careful tests showed that the "undisplaced" particles yielding the central line actually acquired a small velocity imparted to them in the same direction of motion as the moving particles (no more than about 750 meters per second). Under normal circumstances, this would be of no consequence, since this effect would only result in a slight apparent broadening of the direct and reflected images of the central line. But if the mirror were tarnished, the central line might be expected to shift slightly. Other controls were performed to address various objections of critics of the original experiment.

The net result of all of this attention to detail was the complete verification of Ives and Stilwell's 1938 results and the extension of these results to higher speeds.[2]

Mössbauer rotor experiments

The Kündig experiment (1963). An 57Fe Mössbauer absorber was mounted 9.3 cm from the axis of an ultracentrifuge rotor. A 57Co source was mounted on a piezoelectric transducer (PZT) at the rotor center. Spinning the rotor caused the source and absorber to fall out of resonance. A modulated voltage applied to the PZT set the source in radial motion relative to the absorber, so that the amount of conventional Doppler shift that would restore resonance could be measured. For example, withdrawing the source at 195 µm/s produced a conventional Doppler redshift equivalent to the TDE resulting from spinning the absorber at 35,000 rpm.

Relativistic Doppler effect

A more precise confirmation of the relativistic Doppler effect was achieved by the Mössbauer rotor experiments. From a source in the middle of a rotating disk, gamma rays are sent to a receiver at the rim (in some variations this scheme was reversed). Due to the rotation velocity of the receiver, the absorption frequency decreases if the transverse Doppler effect exists. This effect was actually observed using the Mössbauer effect. The maximal deviation from time dilation was 10−5, thus the precision was much higher than that (10−2) of the Ives–Stilwell experiments. Such experiments were performed by Hay et al. (1960),[9] Champeney et al. (1963, 1965),[10][11] Kündig (1963).[12]

Isotropy of the speed of light

Moessbauer rotor experiments were also used to measure a possible anisotropy of the speed of light. That is, a possible aether wind should exert a disturbing influence on the absorption frequency. However, as in all other aether drift experiments (Michelson–Morley experiment), the result was negative, putting an upper limit to aether drift of 3–4 m/s. Experiments of that kind were performed by Champeney & Moon (1961),[13] Champeney et al. (1963)[14] and Turner & Hill (1964).[15]

Modern experiments

Fast moving clocks

A considerably higher precision has been achieved in modern variations of Ives–Stilwell experiments. In heavy ion storage rings, as the TSR at the MPIK, the Doppler shift of lithium ions traveling at high speeds is evaluated by using saturated spectroscopy. Due to their frequencies emitted, these ions can be considered as optical atomic clocks of high precision.

Author Year Speed Maximum deviation from time dilation
Grieser et al.[16]19940.064 c 1.1×106
Saathoff et al.[17]20030.064 c 2.2×107
Reinhardt et al.[18]20070.064 c 8.4×108
Novotny et al.[19]20090.34 c 1.3×106
Botermann et al.[20] 2014 0.338 c  12.3×109

Slow moving clocks

Meanwhile, the measurement of time dilation at everyday speeds has been accomplished as well. Chou et al. (2010) created two clocks each holding a single 27Al+ ion in a Paul trap. In one clock, the Al+ ion was accompanied by a 9Be+ ion as a "logic" ion, while in the other, it was accompanied by a 25Mg+ ion. The two clocks were situated in separate laboratories and connected with a 75 m long, phase-stabilized optical fiber for exchange of clock signals. These optical atomic clocks emitted frequencies in the petahertz (1 PHz = 1015 Hz) range and had frequency uncertainties in the 10−17 range. With these clocks, it was possible to measure a frequency shift due to time dilation of ∼10−16 at speeds below 36 km/h (< 10 m/s, the speed of a fast runner) by comparing the rates of moving and resting aluminum ions. It was also possible to detect gravitational time dilation from a difference in elevation between the two clocks of 33 cm.[21]

References

  1. 1.0 1.1 1.2 Ives, H. E.; Stilwell, G. R. (1938). "An experimental study of the rate of a moving atomic clock". Journal of the Optical Society of America 28 (7): 215. Bibcode:1938JOSA...28..215I. doi:10.1364/JOSA.28.000215.
  2. 2.0 2.1 2.2 Ives, H. E.; Stilwell, G. R. (1941). "An experimental study of the rate of a moving atomic clock. II". Journal of the Optical Society of America 31 (5): 369. Bibcode:1941JOSA...31..369I. doi:10.1364/JOSA.31.000369.
  3. Robertson, H. P. (1949). "Postulate versus Observation in the Special Theory of Relativity". Reviews of Modern Physics 21 (3): 378–382. Bibcode:1949RvMP...21..378R. doi:10.1103/RevModPhys.21.378.
  4. Einstein, Albert (1905). "Zur Elektrodynamik bewegter Körper". Annalen der Physik 322 (10): 891–921. Bibcode:1905AnP...322..891E. doi:10.1002/andp.19053221004. English translation: ‘On the Electrodynamics of Moving Bodies’
  5. Einstein, Albert (1907). "Über die Möglichkeit einer neuen Prüfung des Relativitätsprinzips" (PDF). Annalen der Physik 328 (6): 197–198. Bibcode:1907AnP...328..197E. doi:10.1002/andp.19073280613.
  6. Otting, G. (1939). "Der quadratische Dopplereffekt". Physikalische Zeitschrift 40: 681–687.
  7. Mandelberg, Hirsch I.; Witten, Louis (1962). "Experimental verification of the relativistic doppler effect". Journal of the Optical Society of America 52 (5): 529. Bibcode:1962JOSA...52..529M. doi:10.1364/josa.52.000529.
  8. 8.0 8.1 Hasselkamp, D.; Mondry, E.; Scharmann, A. (1979-06-01). "Direct observation of the transversal Doppler-shift". Zeitschrift für Physik A 289 (2): 151–155. Bibcode:1979ZPhyA.289..151H. doi:10.1007/BF01435932.
  9. Hay, H. J.; Schiffer, J. P.; Cranshaw, T. E.; Egelstaff, P. A. (1960). "Measurement of the Red Shift in an Accelerated System Using the Mössbauer Effect in 57Fe". Physical Review Letters 4 (4): 165–166. Bibcode:1960PhRvL...4..165H. doi:10.1103/PhysRevLett.4.165.
  10. Champeney, D. C.; Isaak, G. R.; Khan, A. M. (1963). "Measurement of Relativistic Time Dilatation using the Mössbauer Effect". Nature 198 (4886): 1186–1187. Bibcode:1963Natur.198R1186C. doi:10.1038/1981186b0.
  11. Champeney, D. C.; Isaak, G. R.; Khan, A. M. (1965). "A time dilatation experiment based on the Mössbauer effect". Proceedings of the Physical Society 85 (3): 583–593. Bibcode:1965PPS....85..583C. doi:10.1088/0370-1328/85/3/317.
  12. Kündig, Walter (1963). "Measurement of the Transverse Doppler Effect in an Accelerated System". Physical Review 129 (6): 2371–2375. Bibcode:1963PhRv..129.2371K. doi:10.1103/PhysRev.129.2371.
  13. Champeney, D. C.; Moon, P. B. (1961). "Absence of Doppler Shift for Gamma Ray Source and Detector on Same Circular Orbit". Proceedings of the Physical Society 77 (2): 350–352. Bibcode:1961PPS....77..350C. doi:10.1088/0370-1328/77/2/318.
  14. Champeney, D. C.; Isaak, G. R.; Khan, A. M. (1963). "An 'aether drift' experiment based on the Mössbauer effect". Physics Letters 7 (4): 241–243. Bibcode:1963PhL.....7..241C. doi:10.1016/0031-9163(63)90312-3.
  15. Turner, K. C.; Hill, H. A. (1964). "New Experimental Limit on Velocity-Dependent Interactions of Clocks and Distant Matter". Physical Review 134 (1B): 252–256. Bibcode:1964PhRv..134..252T. doi:10.1103/PhysRev.134.B252.
  16. Grieser, R.; Klein, R.; Huber, G.; Dickopf, S.; Klaft, I.; Knobloch, P.; Merz, P.; Albrecht, F.; Grieser, M.; Habs, D.; Schwalm, D.; Kühl, T. (1994). "A test of special relativity with stored lithium ions". Applied Physics B Lasers and Optics 59 (2): 127–133. Bibcode:1994ApPhB..59..127G. doi:10.1007/BF01081163.
  17. Saathoff, G.; Karpuk, S.; Eisenbarth, U.; Huber, G.; Krohn, S.; Horta, R. Muñoz; Reinhardt, S.; Schwalm, D.; Wolf, A.; Gwinner, G. (2003). "Improved Test of Time Dilation in Special Relativity". Phys. Rev. Lett. 91 (19): 190403. Bibcode:2003PhRvL..91s0403S. doi:10.1103/PhysRevLett.91.190403.
  18. Reinhardt, S.; Saathoff, G.; Buhr, H.; Carlson, L. A.; Wolf, A.; Schwalm, D.; Karpuk, S.; Novotny, C.; Huber, G.; Zimmermann, M.; Holzwarth, R.; Udem, T.; Hänsch, T. W.; Gwinner, G. (2007). "Test of relativistic time dilation with fast optical atomic clocks at different velocities". Nature Physics 3 (12): 861–864. Bibcode:2007NatPh...3..861R. doi:10.1038/nphys778.
  19. Novotny, C. et al. (2009). "Sub-Doppler laser spectroscopy on relativistic beams and tests of Lorentz invariance". Physical Review A 80 (2): 022107. Bibcode:2009PhRvA..80b2107N. doi:10.1103/PhysRevA.80.022107.
  20. Botermann, Benjamin; Bing, Dennis; Geppert, Christopher; Gwinner, Gerald; Hänsch, Theodor W.; Huber, Gerhard; Karpuk, Sergei; Krieger, Andreas; Kühl, Thomas; Nörtershäuser, Wilfried; Novotny, Christian; Reinhardt, Sascha; Sánchez, Rodolfo; Schwalm, Dirk; Stöhlker, Thomas; Wolf, Andreas; Saathoff, Guido (September 2014). "Test of Time Dilation Using Stored Li+ Ions as Clocks at Relativistic Speed". Physical Review Letters 113 (12): 120405. arXiv:1409.7951. doi:10.1103/PhysRevLett.113.120405.
  21. Chou, C. W.; Hume, D. B.; Rosenband, T.; Wineland, D. J. (2010). "Optical Clocks and Relativity". Science 329 (5999): 1630–1633. Bibcode:2010Sci...329.1630C. doi:10.1126/science.1192720. PMID 20929843.

External links