Wimshurst machine with two Leyden jars.
Suppose that the conditions are as in the figure, with the segment A1 positive and the segment B1 negative. Now, as A1 moves to the left and B1 to the right, their potentials will rise on account of the work done in separating them against attraction. When A1 and neighboring sectors comes opposite the segment B2 of the B plate, which is now in contact with the brush Y, they will cause a displacement of electricity along the conductor between Y and Y1 bringing a negative charge, larger than the positive charge in A1 alone, on Y and sending a positive charge to the segment touching Y1. As A1 moves on, it passes near the brush Z and is partially discharged into the external circuit. It then passes on until, on touching the brush X, has a new charge, this time negative, driven into it by induction from B2 and neighboring sectors. As the machine turns, the process causes exponential increases in the voltages on all positions, until sparking occurs limiting the increase.
Wimshurst maschine at work

The Wimshurst influence machine is an electrostatic generator, a machine for generating high voltages developed between 1880 and 1883 by British inventor James Wimshurst (1832–1903).

It has a distinctive appearance with two large contra-rotating discs mounted in a vertical plane, two crossed bars with metallic brushes, and a spark gap formed by two metal spheres.

Description

These machines belong to a class of electrostatic generators called influence machines, which separate electric charges through electrostatic induction, or influence, not depending on friction for their operation. Earlier machines in this class were developed by Wilhelm Holtz (1865 and 1867), August Toepler (1865), J. Robert Voss (1880), and others. The older machines are less efficient and exhibit an unpredictable tendency to switch their polarity. The Wimshurst does not have this defect.

In a Wimshurst machine, the two insulated discs and their metal sectors rotate in opposite directions passing the crossed metal neutralizer bars and their brushes. An imbalance of charges is induced, amplified, and collected by two pairs of metal combs with points placed near the surfaces of each disk. These collectors are mounted on insulating supports and connected to the output terminals. The positive feedback increases the accumulating charges exponentially until the dielectric breakdown voltage of the air is reached and an electric spark jumps across the gap.

The machine is theoretically not self-starting, meaning that if none of the sectors on the discs has any electrical charge there is nothing to induce charges on other sectors. In practice, even a small residual charge on any sector is enough to start the process going once the discs start to rotate. The machine will only work satisfactorily in a dry atmosphere. It does require mechanical power to turn the disks against the electric field, and it is this energy that the machine converts into electric power. The steady state output of the Wimshurst machine is a direct (non-alternating) current that is proportional to the area covered by the metal sector, the rotation speed, and a complicated function of the initial charge distribution. The insulation and the size of the machine determine the maximum output voltage that can be reached. The accumulated spark energy can be increased by adding a pair of Leyden jars, an early type of capacitor suitable for high voltages, with the jars’ inner plates independently connected to each of the output terminals and the jars’ outer plates interconnected. A typical Wimshurst machine can produce sparks that are about a third of the disc's diameter in length and several tens of microamperes.

In practice slight variations in the disc rotation rates (e.g. due to belt slippage) smooth the output to a steady increments to the Leyden jar charge. The available voltage gain can be understood by noting that the charge density on oppositely charged sectors, between the neutralizer bars, is nearly uniform across the sectors, and thus at low voltage, while the charge density on same charged sectors, approaching the collector combs, peaks near the sector edges, at a consequently high voltage relative to the opposite collector combs.

Operation

The two contra-rotating insulating discs (usually made of glass) have a number of metal sectors stuck onto them. The machine is provided with four small earthed brushes (two on each side of the machine on conducting shafts at 90° to each other), plus a pair of charge-collection combs. The conducting shafts that hold the brushes on a typical Wimshurst machine would form an 'X' on an X-ray photograph; the charge-collection combs are typically mounted along the horizontal and equally contact the outer edges of both front and back discs. The collection combs on each side are usually connected to respective Leyden jars.

Any small charge on either of the two discs suffices to begin the charging process. Suppose, therefore, that the back disc has a small, net electrostatic charge. For concreteness, assume this charge is positive (red) and that the back disc ([A] lower chain) rotates counter-clockwise (right to left). As the charged sector (moving red square) rotates to the position of the brush ([Y] down arrow tip) next to front disc ([B] upper chain near center), it induces a polarization of charge on the conducting shaft ([Y-Y1] upper horizontal black line) holding the brush, attracting negative (green) charge to the near side ([Y] upper square becoming green), so that positive (red) charge accumulates on the far side (across the disc, 180 degrees away) ([Y1] upper square becoming red). The shaft's polarized charges attach to the nearest sectors on disc B, resulting in negative charge on B [Y] closer to the original positive charge on A, and positive charge on the opposite side of B [Y1]. After an additional 45° rotation, the positive (red) charge on A (lower chain) is repelled by a positive (red) charge approaching ([Z] near lower chain middle) a positive (red) charge on B ([Z] upper chain). The first collection comb ([Z] arrow-tipped lines to triangles) encountered allows both positive (red) charges to leave the sectors neutral (squares becoming black), and accumulate in the Leyden jar anode (red triangle) attracted to the Leyden jar cathode (green triangle). The charge completes the cycle across the discs when a spark (yellow zigzag) discharges the Leyden jar (red and green triangles).

As B rotates 90° clockwise (left to right), the charges that have been induced on it line up with the brushes next to disc A [X, X1]. Naturally the charges on B induce the opposite polarization of the A-brushes' shaft (viz., negative next to positive and positive next to negative), and the shaft's polarization is transferred to its disc. Disc B keeps rotating and its charges are accumulated by the nearest charge-collection combs.

Disc A rotates 90° so that its charges line up with the brush of disc B [Y, Y1], where an opposite charge-polarization is induced on the B conducting shaft and the nearest sectors of B, similar to the description two paragraphs above.

The process repeats, with each charge polarization on A inducing polarization on B, inducing polarization on A, etc. All of these induced positive and negative charges are collected by combs to charge the Leyden jars, electrical charge-storage devices similar to capacitors. The mechanical energy required to separate the opposing charges on the adjacent sectors provides the energy source for the electrical output.

See also

References

External links

This article is issued from Wikipedia. The text is available under the Creative Commons Attribution/Share Alike; additional terms may apply for the media files.