Hydrogen leak testing is the normal way in which a hydrogen pressure vessel or installation is checked for leaks or flaws. There are various tests.

  • The Hydrostatic test, The vessel is filled with a nearly incompressible liquid - usually water or oil - and examined for leaks or permanent changes in shape. The test pressure is always considerably more than the operating pressure to give a margin for safety, typically 150% of the operating pressure.
  • The Burst test, The vessel is filled with a gas and tested for leaks. The test pressure is always considerably more than the operating pressure to give a margin for safety, typically 200% or more of the operating pressure.
  • The Helium leak test, The leak detection method uses helium (the lightest inert gas) as a tracer gas and detects it in concentrations as small as one part in 10 million. The helium is selected primarily because it penetrates small leaks readily.
  • Usually a vacuum inside the object is created with an external pump connected to the instrument.
  • Alternatively helium can be injected inside the product while the product itself is enclosed in a vacuum chamber connected to the instrument. In this case Burst and leakage tests can be combined in one operation.
  • The Hydrogen sensor, The object is filled with a mixture of 5% hydrogen/ 95% nitrogen, (below 5.7% hydrogen is non-flammable (ISO-10156). This is called typically a sniffing test. The handprobe connected to the microelectronic hydrogen sensors is used to check the object. An audiosignal increases in proximity of a leak. Detection of leaks go down to 5x10-7 cubic centimeters per second . Compared to the helium test: hydrogen is cheaper than helium, no need for a vacuum, the instrument could be cheaper.