110 block
A 110 block is a type of punch block used to connect sets of wires in a structured cabling system. The "110" designation is also used to describe a type of insulation-displacement connector used to terminate twisted pair cables [1] which uses a similar punch-down tool as the older 66 block.
Usage
Telephone distribution
Early residential telephone systems used simple screw terminals to join cables to sockets in a tree topology. Since the 1980s[citation needed], these screw-terminal blocks have been slowly replaced by 110 blocks and sockets. Modern homes usually have phone service entering the house to a single 110 block, whence it is distributed by on-premises wiring to outlet boxes throughout the home in series or star topology. At the outlet box, cables are punched down to standard RJ-11 sockets, which fit in special faceplates.
In commercial settings, this style of "home run" or "star topology" wiring was already in use on 66 blocks in telecom closets and switchrooms. The 110 block has been slowly replacing the 66 block, especially for data communications usage.
Computer networks
The 110 block is often used at both ends of Category 5 cable runs through buildings, as shown in the image. In switch rooms, 110 blocks are often built into the back of patch panels to terminate cable runs. At the other end, 110 connections may be used with keystone modules that are attached wall plates. 110 blocks are preferred over 66 blocks in high-speed networks because they introduce less crosstalk and many are certified for use in Category 5 and Category 6 wiring systems, even Category 6a.[citation needed]
Advantages
110 style blocks allow a much higher density of terminations in a given space than older style termination blocks (66 style or wire wrap). Some 110 blocks meet specifications for higher bandwidth data protocols such as Category 5 and higher.
Problems
During regular usage, small pieces of insulation can become stuck inside the 110 block contacts; this renders that given pair unreliable or unusable, until the pieces are removed. A tool known as a spudger can be used to remove excess insulation pieces. The wire hook which comes on many punch down tools can also be used to remove wire pieces.
A new wire inserted over an existing insulation remnant will be unable to make reliable contact with the 110 block, which was designed to hold only a single wire per contact.
For testing it is more difficult to reliably connect to a working circuit on a 110 block than on older style blocks. The circuit must be broken, or insulation displacing contacts may be used on jumper wires. Repeated use of insulation displacing contacts may lead to a difficult to locate broken or intermittent jumper wire.