Admittance parameters

Admittance parameters or Y-parameters (the elements of an admittance matrix or Y-matrix) are properties used in electrical engineering, electronic engineering, and communication systems engineering describe the electrical behavior of linear electrical networks. They are also used to describe the small-signal (linearized) response of non-linear networks. They are members of a family of similar parameters used in electronic engineering, other examples being: S-parameters,[1] Z-parameters,[2] H-parameters, T-parameters or ABCD-parameters.[3][4]

Contents

The Y-parameter matrix

A Y-parameter matrix describes the behaviour of any linear electrical network that can be regarded as a black box with a number of ports. A port in this context is a pair of electrical terminals carrying equal and opposite currents into and out-of the network, and having a particular voltage between them. The Y-matrix gives no information about the behaviour of the network when the currents at any port are not balanced in this way (should this be possible), nor does it give any information about the voltage between terminals not belonging to the same port. Typically, it is intended that each external connection to the network is between the terminals of just one port, so that these limitations are appropriate.

For a generic multi-port network definition, it is assumed that each of the ports is allocated an integer n ranging from 1 to N, where N is the total number of ports. For port n, the associated Y-parameter definition is in terms of the port voltage and port current, V_n\, and I_n\, respectively.

For all ports the currents may be defined in terms of the Y-parameter matrix and the voltages by the following matrix equation:

I = Y V\,

where Y is an N × N matrix the elements of which can be indexed using conventional matrix notation. In general the elements of the Y-parameter matrix are complex numbers and functions of frequency. For a one-port network, the Y-matrix reduces to a single element, being the ordinary admittance measured between the two terminals.

Two-port networks

The Y-parameter matrix for the two-port network is probably the most common. In this case the relationship between the port voltages, port currents and the Y-parameter matrix is given by:

{I_1 \choose I_2} = \begin{pmatrix} Y_{11} & Y_{12} \\ Y_{21} & Y_{22} \end{pmatrix}{V_1 \choose V_2} .

where

Y_{11} = {I_1 \over V_1 } \bigg|_{V_2 = 0} \qquad Y_{12} = {I_1 \over V_2 } \bigg|_{V_1 = 0}
Y_{21} = {I_2 \over V_1 } \bigg|_{V_2 = 0} \qquad Y_{22} = {I_2 \over V_2 } \bigg|_{V_1 = 0}

Admittance relations

The input admittance of a two-port network is given by:

Y_{in} = y_{11} - \frac{y_{12}y_{21}}{y_{22}%2BY_L}

where YL is the admittance of the load connected to port two.

Similarly, the output admittance is given by:

Y_{out} = y_{22} - \frac{y_{12}y_{21}}{y_{11}%2BY_S}

where YS is the admittance of the source connected to port one.

Relation to S-parameters

The Y-parameters of a network are related to its S-Parameters by[5]

 \begin{align}
Y &= \sqrt{y} (1_{\!N} - S) (1_{\!N} %2B S)^{-1} \sqrt{y} \\
  &= \sqrt{y} (1_{\!N} %2B S)^{-1} (1_{\!N} - S) \sqrt{y} \\
\end{align}  

and[5]

 \begin{align}
S &= (1_{\!N} - \sqrt{z}Y\sqrt{z}) (1_{\!N} %2B \sqrt{z}Y\sqrt{z})^{-1} \\
  &= (1_{\!N} %2B \sqrt{z}Y\sqrt{z})^{-1} (1_{\!N} - \sqrt{z}Y\sqrt{z}) \\
\end{align}  

where 1_{\!N} is the identity matrix, \sqrt{y} is a diagonal matrix having the square root of the characteristic admittance (the reciprocal of the characteristic impedance) at each port as its non-zero elements,

\sqrt{y} = \begin{pmatrix}
 \sqrt{y_{01}} &  \\
               & \sqrt{y_{02}} \\
               &            & \ddots \\
               &            &           & \sqrt{y_{0N}}
\end{pmatrix}

and \sqrt{z} = (\sqrt{y})^{-1} is the corresponding diagonal matrix of square roots of characteristic impedances. In these expressions the matrices represented by the bracketed factors commute and so, as shown above, may be written in either order.[5][note 1]

Two port

In the special case of a two-port network, with the same characteristic admittance y_{01} = y_{02} = Y_0 at each port, the above expressions reduce to

Y_{11} = {((1 - S_{11}) (1 %2B S_{22}) %2B S_{12} S_{21}) \over \Delta_S} Y_0 \,
Y_{12} = {-2 S_{12} \over \Delta_S} Y_0 \,
Y_{21} = {-2 S_{21} \over \Delta_S} Y_0 \,
Y_{22} = {((1 %2B S_{11}) (1 - S_{22}) %2B S_{12} S_{21}) \over \Delta_S} Y_0 \,

Where

\Delta_S = (1 %2B S_{11}) (1 %2B S_{22}) - S_{12} S_{21} \,

The above expressions will generally use complex numbers for S_{ij} and Y_{ij}. Note that the value of \Delta can become 0 for specific values of S_{ij} so the division by \Delta in the calculations of Y_{ij} may lead to a division by 0.

The two-port S-parameters may also be obtained from the equivalent two-port Y-parameters by means of the following expressions.[6]

S_{11} = {(1 - Z_0 Y_{11}) (1 %2B Z_0 Y_{22}) %2B Z^2_0 Y_{12} Y_{21} \over \Delta} \,
S_{12} = {-2 Z_0 Y_{12} \over \Delta} \,
S_{21} = {-2 Z_0 Y_{21} \over \Delta} \,
S_{22} = {(1 %2B Z_0 Y_{11}) (1 - Z_0 Y_{22}) %2B Z^2_0 Y_{12} Y_{21} \over \Delta} \,

where

\Delta = (1 %2B Z_0 Y_{11}) (1 %2B Z_0 Y_{22}) - Z^2_0 Y_{12} Y_{21} \,

and Z_0 is the characteristic impedance at each port (assumed the same for the two ports).

Relation to Z-parameters

Conversion from Z-parameters to Y-parameters is much simpler, as the Y-parameter matrix is just the inverse of the Z-parameter matrix. The following expressions show the applicable relations:

Y_{11} = {Z_{22} \over \Delta_Z} \,
Y_{12} = {-Z_{12} \over \Delta_Z} \,
Y_{21} = {-Z_{21} \over \Delta_Z} \,
Y_{22} = {Z_{11} \over \Delta_Z} \,

Where

\Delta_Z = Z_{11} Z_{22} - Z_{12} Z_{21} \,

In this case \Delta_Z is the determinant of the Z-parameter matrix.

Vice versa the Y-parameters can be used to determine the Z-parameters, essentially using the same expressions since

Y = Z^{-1} \,

And

Z = Y^{-1} \,

Notes

  1. ^ Any square matrix commutes with itself and with the identity matrix, and if two matrices A and B commute, then so do A and B-1 (since AB-1 = B-1BAB-1 = B-1ABB-1 = B-1A)

References

  1. ^ Pozar, David M. (2005); Microwave Engineering, Third Edition (Intl. Ed.); John Wiley & Sons, Inc.; pp 170-174. ISBN 0-471-44878-8.
  2. ^ Pozar, David M. (2005) (op. cit); pp 170-174.
  3. ^ Pozar, David M. (2005) (op. cit); pp 183-186.
  4. ^ Morton, A. H. (1985); Advanced Electrical Engineering;Pitman Publishing Ltd.; pp 33-72. ISBN 0-273-40172-6
  5. ^ a b c Russer, Peter (2003). Electromagnetics, microwave circuit and antenna design for communications engineering. Artech House. ISBN 1-58053-532-1. 
  6. ^ Simon Ramo, John R. Whinnery, Theodore Van Duzer, "Fields and Waves in Communication Electronics", Third Edition, John Wiley & Sons Inc.; 1993, pp. 537-541, ISBN 0-471-58551-3.

See also