Solar air heating is a solar thermal technology in which the energy from the sun, solar insolation, is captured by an absorbing medium and used to heat air.[1] Solar air heating is a renewable energy heating technology used to heat or condition air for buildings or process heat applications. It is typically the most cost-effective out of all the solar technologies, especially in commercial and industrial applications, and it addresses the largest usage of building energy in heating climates, which is space heating and industrial process heating.
Solar air collectors can be commonly divided into two categories:[2]
Contents |
The term "unglazed air collector" refers to a solar air heating system that consists of a metal absorber without any glass or glazing over top. The most common type of unglazed collector on the market is the transpired solar collector.[3] This technology was invented and patented as SolarWall by Conserval Engineering Inc. in the 1990s, who worked with the U.S. Department of Energy (NREL) and Natural Resources Canada on the commercialization of the technology around the world.[4] The technology has been extensively monitoring by these government agencies, and Natural Resources Canada developed the feasibility tool RETScreen to model the energy savings from transpired solar collectors.
Since that time, several thousand transpired solar collector systems have been installed in a variety of commercial, industrial, institutional, agricultural, and process applications in over 30 countries around the world.[5][6] The technology was originally used primarily in industrial applications such as manufacturing and assembly plants where there were high ventilation requirements, stratified ceiling heat, and often negative pressure in the building. The first unglazed transpired collector in the world was installed by Ford Motor Company on their assembly plant in Oakville, Canada.[7]
With the increasing drive to install renewable energy systems on buildings, transpired solar collectors are now used across the entire building stock because of high energy production (up to 500-600 peak thermal Watts/square metre), high solar conversion (up to 80%) and lower capital costs when compared against solar photovoltaic and solar water heating.[8]
Unglazed air collectors heat ambient (outside) air instead of recirculated building air. Transpired solar collectors are usually wall-mounted to capture the lower sun angle in the winter heating months as well as sun reflection off the snow. The exterior surface of a transpired solar collector consists of thousands of tiny micro-perforations that allow the boundary layer of heat to be captured and uniformly drawn into an air cavity behind the exterior panels. This heated ventilation air is drawn under negative pressure into the building’s ventilation system where it is then distributed via conventional means or using a solar ducting system. The extensive monitoring by Natural Resources Canada and NREL has shown that transpired solar collector systems reduce between 10-50% of the conventional heating load and that RETScreen 3.1 is an accurate predictor of system performance.[9]
Transpired solar collectors act as a rainscreen and they also capture heat loss escaping from the building envelope which is collected in the collector air cavity and drawn back into the ventilation system. There is no maintenance required with solar air heating systems and the expected lifespan is over 30 years.[10]
Unglazed transpired collectors can also be roof-mounted for applications in which there is not a suitable south facing wall or to avoid architectural considerations. In these cases the heat from the system is ducted along the roof to the nearest air handling unit.
Transpired solar collectors can also be combined with photovoltaic (PV) panels to create a hybrid solar system. The heat from the back of the PV modules (which is often 4 times more than the electrical energy produced by the PV module) is removed by the solar air system (which doubles as the PV racking system) and is used for building heating purposes. In cases where there is a heating requirement, incorporating a solar air component into the PV system produces two technical advantages; it removes the PV heat and allows the PV system to operate at its rated efficiency (which is 25C); and it decreases the total energy payback period associated with the combined system because the heat energy is captured and used to offset conventional heating.
Research is also being done by Conserval Engineering in terms of using the transpired solar collector for nighttime cooling.[7][11][12]
Functioning in a similar manner as a conventional forced air furnace, systems provide heat by recirculating conditioned building air through solar collectors - Solar thermal collectors. Through the use of an energy collecting surface to absorb the sun’s thermal energy, and ducting air to come in contact with it, a simple and effective collector can be made for a variety of air conditioning and process applications.
A simple solar air collector consists of an absorber material, sometimes having a selective surface, to capture radiation from the sun and transfers this thermal energy to air via conduction heat transfer. This heated air is then ducted to the building space or to the process area where the heated air is used for space heating or process heating needs.
Due to varying air-ducting methods, collectors are commonly classified as one of three types:
In the through-pass configuration, air ducted onto one side of the absorber passes through a perforated or fibrous type material and is heated from the conductive properties of the material and the convective properties of the moving air. Through-pass absorbers have the most surface area which enables relatively high conductive heat transfer rates, but significant pressure drop can require greater fan power, and deterioration of certain absorber material after many years of solar radiation exposure can additionally create problems with air quality and performance.
In back-pass, front-pass, and combination type configurations the air is directed on either the back, the front, or on both sides of the absorber to be heated from the return to the supply ducting headers. Although passing the air on both sides of the absorber will provide a greater surface area for conductive heat transfer, issues with dust (fouling) can arise from passing air on the front side of the absorber which reduces absorber efficiency by limiting the amount of sunlight received. In cold climates, air passing next to the glazing will additionally cause greater heat loss, resulting in lower overall performance of the collector.
A variety of applications can utilize solar air heat technologies to reduce the carbon footprint from use of conventional heat sources, such as fossil fuels, to create a sustainable means to produce thermal energy. Applications such as space heating, greenhouse season extension, pre-heating ventilation makeup air, or process heat can be addressed by solar air heat devices.[13] In the field of ‘solar co-generation’ solar thermal technologies are paired with photovoltaics (PV) to increase the efficiency of the system by cooling the PV panels to improve their electrical performance while simultaneously warming air for space heating.
Space heating for residential and commercial applications can be done through the use of solar air heating panels. This configuration operates by drawing air from the building envelope or from the outdoor environment and passing it through the collector where the air warms via conduction from the absorber and is then supplied to the living or working space by either passive means or with the assistance of a fan.
Ventilation, fresh air or makeup air is required in most commercial, industrial and institutional buildings to meet code requirements. By drawing air through a properly designed unglazed transpired air collector or an air heater the solar heated fresh air can reduce the heating load during daytime operation. Many applications are now being installed where the transpired collector preheats the fresh air entering a heat recovery ventilator to reduce the defrost time of HRV's.
Solar air heat can also be used in process applications such as drying laundry, crops (i.e. tea, corn, coffee) and other drying applications. Air heated through a solar collector and then passed over a medium to be dried can provide an efficient means by which to reduce the moisture content of the material.