Slow sand filter

Slow sand filters are used in water purification for treating raw water to produce a potable product. They are typically 1 to 2 metres deep, can be rectangular or cylindrical in cross section and are used primarily to treat surface water. The length and breadth of the tanks are determined by the flow rate desired by the filters, which typically have a loading rate of 0.1 to 0.2 metres per hour (or cubic metres per square metre per hour). Although they are often the preferred technology in many developing countries, they are also used to treat water in some of the most developed countries such as the UK where they are used to treat water supplied to London. Slow sand filters now are also being tested for pathogen control of nutrient solutions in hydroponic systems.

Contents

Features

Slow sand filters have a number of unique qualities:

  1. Unlike other filtration methods, slow sand filters use biological processes to clean the water, and are non-pressurized systems. Slow sand filters do not require chemicals or electricity to operate.
  2. Cleaning is traditionally by use of a mechanical scraper, which is usually driven into the filter bed once it has been dried out. However, some slow sand filter operators use a method called "wet harrowing", where the sand is scraped while still under water, and the water used for cleaning is drained to waste;
  3. For municipal systems there usually is a certain degree of redundancy, it is desirable for the maximum required throughput of water to be achievable with one or more beds out of service;
  4. Slow sand filters require relatively low turbidity levels to operate efficiently. In summer conditions and in conditions when the raw water is turbid, blinding of the filters occurs more quickly and pre-treatment is recommended.
  5. Unlike other water filtration technologies that produce water on demand, slow sand filters produce water at a slow, constant flow rate and are usually used in conjunction with a storage tank for peak usage. This slow rate is necessary for healthy development of the biological processes in the filter.[1]:38-41 [2]

While many municipal water treatment works will have 12 or more beds in use at any one time, smaller communities or households may only have one or two filter beds.

In the base of each bed is a series of herringbone drains that are covered with a layer of pebbles which in turn is covered with coarse gravel. Further layers of sand are placed on top followed by a thick layer of fine sand. The whole depth of filter material may be more than 1 metre in depth, the majority of which will be fine sand material. On top of the sand bed sits a supernatant layer of raw, unfiltered water.

How it works

Slow sand filters work through the formation of a gelatinous layer (or biofilm) called the hypogeal layer or Schmutzdecke in the top few millimetres of the fine sand layer. The Schmutzdecke is formed in the first 10–20 days of operation[3] and consists of bacteria, fungi, protozoa, rotifera and a range of aquatic insect larvae. As a Schmutzdecke ages, more algae tend to develop and larger aquatic organisms may be present including some bryozoa, snails and Annelid worms. The Schmutzdecke is the layer that provides the effective purification in potable water treatment, the underlying sand providing the support medium for this biological treatment layer. As water passes through the Schmutzdecke, particles of foreign matter are trapped in the mucilaginous matrix and dissolved organic material is adsorbed and metabolised by the bacteria, fungi and protozoa. The water produced from a well-managed slow sand filter can be of exceptionally good quality with 90-99% bacterial reduction.[4]

Slow sand filters slowly lose their performance as the Schmutzdecke grows and thereby reduces the rate of flow through the filter. Eventually it is necessary to refurbish the filter. Two methods are commonly used to do this. In the first, the top few millimetres of fine sand is scraped off to expose a new layer of clean sand. Water is then decanted back into the filter and re-circulated for a few hours to allow a new Schmutzdecke to develop. The filter is then filled to full depth and brought back into service.[4] The second method, sometimes called wet harrowing, involves lowering the water level to just above the Schmutzdecke, stirring the sand and thereby suspending any solids held in that layer and then running the water to waste. The filter is then filled to full depth and brought back into service. Wet harrowing can allow the filter to be brought back into service more quickly. [3]

Advantages

Disadvantages

See also

References

  1. ^ a b United States Environmental Protection Agency (EPA)(1990). Cincinnati, OH. "Technologies for Upgrading Existing or Designing New Drinking Water Treatment Facilities." Document no. EPA/625/4-89/023.
  2. ^ HDR Engineering (2001). Handbook of Public Water Systems. New York: John Wiley and Sons. p. 353. ISBN 9780471292111. http://books.google.com/books?id=ieg7lvujyt0C&. Retrieved 2010-03-28. 
  3. ^ a b Centre for Affordable Water and Sanitation Technology, Biosand Filter Manual: Design, Construction, & Installation," July 2007.
  4. ^ a b National Drinking Water Clearinghouse (U.S.), Morgantown, WV. "Slow Sand Filtration." Tech Brief Fourteen, June 2000.
  5. ^ DIY slow sand filter

External links