The kilowatt hour, or kilowatt-hour, (symbol kW·h, kW h or kWh) is a unit of energy equal to 1000 watt hours or 3.6 megajoules.[1][2] For constant power, energy in watt hours is the product of power in watts and time in hours. The kilowatt hour is most commonly known as a billing unit for energy delivered to consumers by electric utilities.
Contents |
The kilowatt-hour (symbolized kWh) is a unit of energy equivalent to one kilowatt (1 kW) of power expended for one hour (1 h) of time.
Inversely, one watt is equal to 1 J/s. One kilowatt hour is 3.6 megajoules, which is the amount of energy converted if work is done at an average rate of one thousand watts for one hour.
A heater rated at 1000 watts (1 kilowatt), operating for one hour uses one kilowatt hour (equivalent to 3.6 megajoules) of energy.
Using a 60 watt light bulb for one hour consumes 0.06 kilowatt hours of electricity. Using a 60 watt light bulb for 1 thousand hours consumes 60 kilowatt hours of electricity.
The international standard for SI[3] states that in a forming a compound unit symbol, "Multiplication must be indicated by a space or a half-high (centered) dot (·), since otherwise some prefixes could be misinterpreted as a unit symbol" (i.e., kW h or kW·h). This is supported by a voluntary standard[4] issued jointly by an international (IEEE) and national (ASTM) organization. However, at least one major usage guide[5] and the IEEE/ASTM standard allow "kWh" (but do not mention other multiples of the watt hour). One guide published by NIST specifically recommends avoiding "kWh" "to avoid possible confusion".[6] Nonetheless, it is commonly used in commercial, educational, scientific and media publications.[7]
To convert a quantity measured in a unit in the left column to the units in the top row, multiply by the factor in the cell where the row and column intersect.
joule | watt hour | electronvolt | calorie | |
---|---|---|---|---|
1 J = 1 kg·m2 s−2 = | 1 | 2.77778 × 10−4 | 6.241 × 1018 | 0.239 |
1 W·h = | 3600 | 1 | 2.247 × 1022 | 859.8 |
1 eV = | 1.602 × 10−19 | 4.45 × 10−23 | 1 | 3.827 × 10−20 |
1 cal = | 4.1868 | 1.163 × 10−3 | 2.613 × 1019 | 1 |
The kilowatt hour is commonly used by electrical distribution providers for purposes of billing, since the monthly energy consumption of a typical residential customer ranges from a few hundred to a few thousand kilowatt hours. Megawatt hours, gigawatt hours, and terawatt hours are often used for metering larger amounts of electrical energy to industrial customers and in power generation. The terawatt hour and petawatt hour are large enough to conveniently express annual electricity generation for whole countries.
Submultiples | Multiples | |||||
---|---|---|---|---|---|---|
Value | Symbol | Name | Value | Symbol | Name | |
10-3 | mW·h | milliwatt hour | 103 | kW·h | kilowatt hour | |
10-6 | µW·h | microwatt hour | 106 | MW·h | megawatt hour | |
109 | GW·h | gigawatt hour | ||||
1012 | TW·h | terawatt hour | ||||
1015 | PW·h | petawatt hour |
In India, the kilowatt hour is often simply called a Unit of energy. A million units, designated MU, is a gigawatt hour and a BU (billion units) is a terawatt hour.[8][9]
Several other units are commonly used to indicate power or energy capacity or use in specific application areas. All the SI prefiexes may be applied to the watt-hour: a megawatt hour is 1 million W·h, (symbols MW·h, MWh) a milliwatt hour is 1/1000 W·h, and has the symbol mW·h or mWh, and so on.
Average annual power production or consumption can be expressed in kilowatt hours per year; for example, when comparing the energy efficiency of household appliances whose power consumption varies with time or the season of the year, or the energy produced by a distributed power source. One kilowatt hour per year equals about 114.08 milliwatts applied constantly during one year.
The energy content of a battery is usually expressed indirectly by its capacity in ampere hours; to convert watt hours (W·h) to ampere hour (A·h), the watt hour value must be divided by the voltage of the power source. This value is approximate since the voltage is not constant during discharge of a battery.
The Board of Trade unit (BOTU) is an obsolete UK synonym for kilowatt hour. The term derives from the name of the Board of Trade that regulated the electricity industry until 1942 when the Ministry of Power took over.[10] The B.O.T.U. should not be confused with the British thermal unit or BTU, which is a much smaller quantity of thermal energy. To further the confusion, at least as late as 1937, Board of Trade unit was simply abbreviated BTU.
Burnup of nuclear fuel is normally quoted in megawatt-days per tonne (MWd/MTU), where tonne refers to a metric ton of uranium metal or its equivalent, and megawatt refers to the entire thermal output, not the fraction which is converted to electricity.
The terms power and energy are frequently confused. Power is the rate at which energy is generated or consumed. Power therefore has the unit watts, which is joules per second. A unit of energy is kilowatt hour.
For example, when a light bulb with a power rating of 100W is turned on for one hour, the energy used is 100 watt hours (W·h), 0.1 kilowatt hour, or 360 kJ. This same amount of energy would light a 40-watt bulb for 2.5 hours, or a 50-watt bulb for 2 hours. A power station would be rated in multiples of watts, but its annual energy sales would be in multiples of watt hours. A kilowatt hour is the amount of energy equivalent to a steady power of 1 kilowatt running for 1 hour, or 3.6 MJ.
Power units measure the rate of energy per unit time. Many compound units for rates explicitly mention units of time, for example, miles per hour, kilometers per hour, dollars per hour. Kilowatt hours are a product of power and time, not a rate of change of power with time. Terms such as watts per hour are often misused.[11] Watts per hour (W/h) is a unit of a change of power per hour. It might be used to characterize the ramp-up behavior of power plants. For example, a power plant that reaches a power output of 1 MW from 0 MW in 15 minutes has a ramp-up rate of 4 MW/h. Hydroelectric power plants have a very high ramp-up rate, which makes them particularly useful in peak load and emergency situations.
Major energy production or consumption is often expressed as terawatt hours for a given period that is often a calendar year or financial year. One terawatt hour is equal to a sustained power of approximately 114 megawatts for a period of one year.