Thermopower
From Wikipedia, the free encyclopedia
This article does not cite any references or sources. (November 2007) Please help improve this article by adding citations to reliable sources. Unverifiable material may be challenged and removed. |
The thermopower, or thermoelectric power (also called the Seebeck coefficient) of a material is a measure of the magnitude of an induced thermoelectric voltage in response to a temperature difference across that material. The thermopower has units of (V / K).
The term thermopower is a misnomer since it measures the voltage or electric field (not the electric power) induced in response to a temperature difference.
Contents |
[edit] Physics of thermopower
Classically, an applied temperature difference causes charged carriers in the material, whether they be electrons or holes, to diffuse from the hot side to the cold side, similar to a gas that expands when heated.
Mobile charged carriers migrating to the cold side leave behind their oppositely charged and immobile nuclei at the hot side thus giving rise to a thermoelectric voltage (thermoelectric refers to the fact that the voltage is created by a temperature difference). Since a separation of charges also creates an electric field, the buildup of charged carriers onto the cold side eventually ceases at some maximum value since there exists an equal amount of charged carriers drifting back to the hot side as a result of the electric field at equilibrium. Only an increase in the temperature difference can resume a buildup of more charge carriers on the cold side and thus lead to an increase in the thermoelectric voltage. Incidentally the thermopower also measures the entropy per charge carrier in the material.
The thermopower of a material, represented as S, depends on the material's temperature, and crystal structure. Typically metals have small thermopowers because most have half-filled bands. Electrons (negative charges) and holes (positive charges) both contribute to the induced thermoelectric voltage thus canceling each other's contribution to that voltage and making it small. In contrast, semiconductors can be doped with an excess amount of electrons or holes and thus can have large positive or negative values of the thermopower depending on the charge of the excess carriers. The sign of the thermopower can determine which charged carriers dominate the electric transport in both metals and semiconductors.
Superconductors have zero thermopower since the charged carriers carry no entropy. Equivalently, the thermopower is zero because it is impossible to have a finite voltage across a superconductor. (For example, by Ohm's law, V=IR=0, since the resistance, R, is equal to zero in a superconductor.)
[edit] Definition
If the temperature difference ΔT between the two ends of a material is small, then the thermopower of a material is defined as:
where ΔV is the thermoelectric voltage seen at the terminals. (See below for more on the signs of ΔV and ΔT.)
This can also be written in relation to the electric field E and the temperature gradient , by the equation:
[edit] Sign of the thermopower
Here, again, are the formulas for the Seebeck coefficient, with the sign made explicit:
where "left" and "right" denote two ends of the material, and where the second equation is understood as vector multiplication. Thus, if S is positive, the end with the higher temperature has the lower voltage, and vice-versa, and the electric field will point in the same direction as the temperature gradient.
Note that there is a minus sign in the first equation, but not the second. This is because the electric field points from the higher voltage towards the lower voltages, whereas the temperature gradient points from the lower temperature towards the higher temperature.
Charge carriers tend to respond to a temperature gradient by moving in the opposite direction, i.e. from the hot end to the cold end. They tend to respond to an electric field in different ways depending on their charge: positive charges tend to move in the same direction as the field, while negative charges move in the opposite direction of the field. For equilibrium to be reached, these two tendencies have to cancel out. Thus, for purely p-type materials which have only positive mobile charges (holes), the electric field and temperature gradient should point in the same direction in equilibrium, giving S>0. Likewise, for purely n-type materials which have only negative mobile charges (electrons), the electric field and temperature gradient should point in opposite directions in equilibrium, giving S<0. In practice, real materials often have both positive and negative charge-carriers, and the sign of S usually depends on which of them predominates.
[edit] Measurement
- See also: Thermocouple
In practice one rarely measures the absolute thermopower of the material of interest. This is because electrodes attached to a voltmeter must be placed onto the material in order to measure the thermoelectric voltage. The temperature gradient then also typically induces a thermoelectric voltage across one leg of the measurement electrodes. Therefore the measured thermopower is a contribution from the thermopower of the material of interest and the material of the measurement electrodes. This arrangement of two materials is usually called a thermocouple.
The measured thermopower is then a contribution from both and can be written as:
Superconductors have zero thermopower, as mentioned above. By using superconducting leads, it is possible to get a direct measurement of the absolute thermopower of the material of interest, since it is the thermopower of the entire thermocouple as well.
A measurement of the Thomson coefficient, μ, of a material can also yield the thermopower through the relation:
[edit] Thermoelectric power generation
The thermoelectric effect is sometimes used to generate electrical power, starting from a source of a temperature gradient. For example, some spacecraft are powered in this way, exploiting the temperature difference between a radioactively-heated plate and the cold empty space surrounding the craft. Some researchers hope that, in the future, much wider use could be made of thermoelectric power generation, including using waste heat from automobiles and power plants.
The efficiency with which a thermoelectric material can generate electrical power depends on several material properties, of which perhaps the most important is the thermopower. A larger induced thermoelectric voltage for a given temperature gradient will lead to a higher efficiency. Ideally one would want very large thermopower values since only a small amount of heat is then necessary to create a large voltage. This voltage can then be used to provide power.
[edit] Materials with High Seebeck Coefficient
- Bismuth telluride
- Uranium dioxide
- Perovskite is a class of compounds including SrRuO3 for which the Seebeck coefficient equals 36 μV K−1 (microvolts per kelvin) at room temperature[1].