Quarter inch cartridge

From Wikipedia, the free encyclopedia

Quarter inch cartridge tape (abbreviated QIC, commonly pronounced "quick") is a magnetic tape data storage format introduced by 3M in 1972, with derivatives still in use as of 2007. QIC comes in a rugged enclosed package of aluminum and plastic that holds two tape reels driven by a single belt in direct contact with the tape. The tape was originally one quarter inch (1/4") wide and anywhere from 300 to 1500 feet long. Data is written to tape in linear tracks in what is called "serpentine" mode, where the tracks alternate direction by use of a head switch or step. Since the introduction of the format, QIC has been widely used and many variations exist. There is a QIC trade association that publishes QIC standards which include interfaces and logical formats, to a very large extent it was the efficiency and openness of this organisation which encouraged hardware and software developers to use this type of drive and media.

Quarter-Inch minicartridges: left, 400MB (QIC-EX); right, 120MB (QIC-80).
Quarter-Inch minicartridges: left, 400MB (QIC-EX); right, 120MB (QIC-80).

Contents

[edit] Features of QIC

The QIC cartridge is distinguished from other types of tape cartridges by the fact that it contains an endless drive belt which is moved at a uniform speed by a motorised capstan. Since the belt is in contact with the tape, this ensures both that the tape moves at uniform speed, and that neutral tension is maintained at all times. This is in contrast to cassette tapes or DATs where the tape is moved past the head by a capstan and pinch wheel, but the takeup reel is driven by a servo motor or slipping clutch.

The tape in a QIC cartridge is not physically attached to the reels, but relies on the fact that it is never completely unwound. This is again different from other cassettes or cartridges, which generally have some form of clip anchoring at least one end of the tape. To ensure that the tape is never completely unwound, each end has a small BOT or EOT (beginning or end of tape) hole which is detected by an optical sensor, and an "early warning" hole further from each end. If a defective drive—for example with fluff in a sensor—winds the tape past the BOT or EOT marker, the tape will detach from the spool and the cartridge will be unusable. It is a relatively simple matter to reattach the tape.

The design of the QIC tape cartridge is very robust: the aluminium baseplate is an eighth of an inch thick, and the robust plastic cover can withstand abuse and impacts that would damage other tape formats.

However, because the tape is belt-driven, seeking back and forth can eventually cause the belt to become unevenly tensioned. It is therefore necessary to periodically "retension" the cartridge. This is accomplished by winding the tape from beginning to end and back in one operation, allowing the belt to equalize itself. For newer QIC drives which use the SCSI interface, there is a standard SCSI "RETENSION" command to accomplish this.

When the cartridge gets old, the belt may not provide enough friction to turn the takeup spool smoothly. When this happens, the tape will need to be replaced.

In some cases a cartridge must be formatted before use, and occasionally during its life; the "intelligence" to do this is in the drive rather than the host computer.

[edit] Generations

[edit] 3M Data Cartridge (DC)

The first QIC tape format was the 5.875 in by 3.875 in (150 x 99mm) Data Cartridge (DC) format with two internal belt-driven reels and a metal base. The original product, the DC300, had 300 feet of tape and held 200 kilobytes. Various QIC DC recording formats have appeared over the years, including:

  • QIC-11: a four-track format giving 20 MB on a 450 ft DC300XL cartridge
  • QIC-24: nine-track, 45 MB or 60MB on a 450 or 600 ft (DC600A) cartridge respectively
  • QIC-120: 15-track, 125 MB on a DC600A
  • QIC-150: 18-track, 150 MB, DC6150 cartridge
  • QIC-525: 26-track, 525 MB on a 1000 ft DC6525 cartridge

Other QIC DC standards included the QIC-02 and QIC-36 drive interface standards. Later QIC DC drives usually used the SCSI interface.

[edit] QIC Mini Cartridge (MC)

Later, the smaller Minicartridge (MC) form-factor was introduced. This was 2.375 in by 3.125 in (61 x 80mm) size and was small enough to fit in a 3.5 in drive bay.

  • QIC-40: 40 MB
  • QIC-80: 80 MB

The QIC-40 and QIC-80 were designed to use the same controller as a standard floppy drive, with MFM or RLL encoding.

[edit] Travan (TR)

Main article: Travan

Travan is an evolution of the QIC Minicartridge format, sold for personal computer use. This version, developed by 3M, uses a longer and wider (8 mm) tape to give higher capacities.

Format Capacity (MB) Speed (kB/s) Tracks
QIC-80 80-500 62.5 28/36
TR-1 400 62.5 36
QIC-3010 340 62.5 40/50
TR-2 800 62.5 50
QIC-3020 670 62.5 40/50
TR-3 1,600 125 50
QIC-3080 1,200-1,600 125 60/72
TR-4 4,000 1024 72
QIC-3095 4,000 1024 72
TR-5 10,000 1024 108

[edit] SLR

SLR is Tandberg Data's name for its line of high-capacity QIC data cartridge drives. As of 2005, Tandberg was the only manufacturer of SLR/QIC drives in the world. The largest SLR drive can hold 70 GB of data (140 GB compressed).

[edit] QIC-Wide

A variant from Sony that uses a wider .315 inch (8 mm) tape and increases the recording density. QIC-Wide drives are backwards compatible with QIC tapes.

[edit] QIC-EX

QIC Extra, a modification to support longer tapes and thus more data by the Verbatim Corporation, this was made possible by making the cartridges physically longer to accommodate larger spools. In many cases a standard QIC drive and backup package can use the extended length to store additional data, however in some cases an attempt to reformat a QIC-EX cartridge fails since the time taken to traverse the extra length triggers a timeout in the drive or controlling software intended to detect a broken tape.

[edit] QIC-157

An interface standard for tape drives using the ATAPI (IDE) interface.

[edit] External links