Image:PowerStation2.svg

From Wikipedia, the free encyclopedia

PowerStation2.svg (SVG file, nominally 3000 × 2063 pixels, file size: 456 KB)

Wikimedia Commons logo This is a file from the Wikimedia Commons. The description on its description page there is shown below.
Commons is a freely licensed media file repository. You can help.

Contents

[edit] Key

1. Cooling tower 10. Steam governor valve 19. Superheater
2. Cooling water pump 11. High pressure turbine 20. Forced draught fan
3. Transmission line (3-phase) 12. Deaerator 21. Reheater
4. Unit transformer (3-phase) 13. Feed heater 22. Air intake
5. Electric generator (3-phase) 14. Coal conveyor 23. Economiser
6. Low pressure turbine 15. Coal hopper 24. Air preheater
7. Condensate extraction pump 16. Pulverised fuel mill 25. Precipitator
8. Condensor 17. Boiler drum 26. Induced draught fan
9. Intermediate pressure turbine 18. Ash hopper 27. Chimney Stack

[edit] Description

A coal-fired thermal power plant.

Coal is conveyed (14) from an external stack and ground to a very fine powder by large metal spheres in the pulverised fuel mill (16). There it is mixed with preheated air (24) driven by the forced draught fan (20). The hot air-fuel mixture is forced at high pressure into the boiler where it rapidly ignites. Water of a high purity flows vertically up the tube-lined walls of the boiler, where it turns into steam, and is passed to the boiler drum, where steam is separated from any remaining water. The steam passes through a manifold in the roof of the drum into the pendant superheater (19) where its temperature and pressure increase rapidly to around 200 bar and 570°C, sufficient to make the tube walls glow a dull red. The steam is piped to the high pressure turbine (11), the first of a three-stage turbine process. A steam governor valve (10) allows for both manual control of the turbine and automatic set-point following. The steam is exhausted from the high pressure turbine, and reduced in both pressure and temperature, is returned to the boiler reheater (21). The reheated steam is then passed to the intermediate pressure turbine (9), and from there passed directly to the low pressure turbine set (6). The exiting steam, now a little above its boiling point, is brought into thermal contact with cold water (pumped in from the cooling tower) in the condensor (8), where it condenses rapidly back into water, creating near vacuum-like conditions inside the condensor chest. The condensed water is then passed by a feed pump (7) through a deaerator (12), and pre-warmed, first in a feed heater (13) powered by steam drawn from the high pressure set, and then in the economiser (23), before being returned to the boiler drum. The cooling water from the condensor is sprayed inside a cooling tower (1), creating a highly visible plume of water vapor, before being pumped back to the condensor (8) in cooling water cycle.

The three turbine sets are sometimes

coupled on the same shaft as the three-phase electrical generator (5) which generates an intermediate level voltage (typically 20-25 kV). This is stepped up by the unit transformer (4) to a voltage more suitable for transmission (typically 250-500 kV) and is sent out onto the three-phase transmission system (3).  

Exhaust gas from the boiler is drawn by the induced draft fan (26) through an electrostatic precipitator (25) and is then vented through the chimney stack (27).

Description

A coal-fired thermal power station.

Source importée de
English:
 : http://en.wikipedia.org/wiki/Image:PowerStation2.svg
Date
Author

en:User:BillC

Permission
(Reusing this image)

see below



I, the copyright holder of this work, has published or hereby publishes it under the following license:
GNU head Permission is granted to copy, distribute and/or modify this document under the terms of the GNU Free Documentation License, Version 1.2 or any later version published by the Free Software Foundation; with no Invariant Sections, no Front-Cover Texts, and no Back-Cover Texts.

Subject to disclaimers.


Asturianu | Български | Català | Deutsch | English | Español | Français | Gaeilge | Italiano | 한국어 | 日本語 | Polski | Português | Română | Türkçe | +/-

[edit] References

  • (1982) Modern Power Station Practice, vol 1:Planning & Layout; vol 2:Boilers, Fuel & Ash-handling plant; vol 3: Turbines & Auxiliary Equipment, Oxford: Pergamon. ISBN 0-08-016436-6.
  • RWE npower Didcot Power Stations
  • Drax Power Ltd How Drax works

[edit] Historique

Date/Time User Dimensions File size Comment (current) 09:04, 29 August 2007 Magicflame (Talk | contribs) 3000×2063 456 KB Reverted to version as of 10:24, 21 June 2006 (revert) 12:12, 21 June 2006 BillC (Talk | contribs) 3000×2063 456 KB Fix issue with text sizing (revert) 10:24, 21 June 2006 BillC (Talk | contribs) 3000×2063 456 KB Coal-fired thermal power station.

File history

Click on a date/time to view the file as it appeared at that time.

Date/TimeDimensionsUserComment
current20:02, 1 October 20073,000×2,063 (456 KB)MaCRoEco ({{Information |Description= A coal-fired thermal power station. |Source= importée de {{en}} : http://en.wikipedia.org/wiki/Image:PowerStation2.svg |Date= |Author= en:User:BillC |Permission= |other_versions= }} {{GFDL-self-with-disclaimers}} == His)
The following pages on the English Wikipedia link to this file (pages on other projects are not listed):