Mass-to-charge ratio
From Wikipedia, the free encyclopedia
The mass-to-charge ratio, is a physical quantity that is widely used in the electrodynamics of charged particles, e.g. in electron optics and ion optics. It appears in the scientific fields of lithography, electron microscopy, cathode ray tubes, accelerator physics, nuclear physics, auger spectroscopy, cosmology and mass spectrometry. The importance of the mass-to-charge ratio, according to classical electrodynamics, is that two particles with the same mass-to-charge ratio move in the same path in a vacuum when subjected to the same electric and magnetic fields.
Contents |
[edit] Origin
When charged particles move in electric and magnetic fields the following two laws apply:
- (Newton's second law of motion)
where F is the force applied to the ion, m is the mass of the ion, a is the acceleration, Q is the ionic charge, E is the electric field, and v x B is the vector cross product of the ion velocity and the magnetic field.
Using Newton's third law of motion yields:
This differential equation is the classic equation of motion of charged particles in vacuum. Together with the particles initial conditions it determines the particle's motion in space and time. It immediately reveals that two particles with the same m/Q behave the same. This is why the mass-to-charge ratio is an important physical quantity in those scientific fields where charged particles interact with magnetic (B) or electric (E) fields.
[edit] Exceptions
There are non-classical effects that derive from quantum mechanics such as the Stern–Gerlach effect that can diverge the path of ions of identical m/Q.
[edit] Symbols & Units
The official symbol for mass is m. The official symbol for electric charge is Q; however, q is also very common. Charge is a scalar property, meaning it can be either positive (+ symbol) or negative (- symbol). Sometimes, however, the sign of the charge is indicated indirectly. Coulomb is the SI unit of charge, however, other units are not uncommon.
The SI unit of the physical quantity m / Q is kilogram per coulomb.
- [m / Q] = kg/C
In the field of mass spectrometry the units and notation above are used in the physics of mass spectrometery while the unitless m/z notation is used as the independent variable that the mass spectrometer measures. These notations are closely related through the unified atomic mass unit and the elementary charge. See Mass spectrum.
[edit] History
In the 19th century the mass-to-charge ratio of some ions were measured by electrochemical methods. In 1897 the mass-to-charge ratio m / e of the electron was first measured by J. J. Thomson.[1] By doing this he showed that the electron, which was postulated before in order to explain electricity, was in fact a particle with a mass and a charge and that its mass-to-charge ratio was much smaller than that of the hydrogen ion H+. In 1898 Wilhelm Wien separated ions (canal rays) according to their mass-to-charge ratio with an ion optical device with superimposed electric and magnetic fields (Wien filter). In 1901 Walter Kaufman measured the relativistic mass increase of fast electrons. In 1913 J. J. Thomson measured the mass-to-charge ratio of ions with an instrument he called a parabola spectrograph.[2] Today, an instrument that measures the mass-to-charge ratio of charged particles is called mass spectrometer.
[edit] Mass-to-charge ratio
The mass-to-charge ratio (Q/m) of an object is, as its name implies, the charge of an object divided by the mass of the same object. This quantity is generally useful only for objects which may be treated as particles. For extended objects, total charge, charge density, total mass, and mass density are often more useful.
[edit] Significance
In some experiments, the mass-to-charge ratio is the only quantity that can be measured directly. Often, the charge can be inferred from theoretical considerations, so that the charge-to-mass ratio provides a way to calculate the mass of a particle.
Often, the mass-to-charge ratio can be determined from observing the deflection of a charged particle in an external magnetic field. The cyclotron equation combined with other information, such as the kinetic energy of the particle, will give the charge-to-mass ratio. One application of this principle is the mass spectrometer. The same principle can be used to extract information in experiments involving the Wilson cloud chamber.
The ratio of electrostatic to gravitational forces between two particles will be proportional to the product of their charge-to-mass ratios. It turns out that gravitational forces are comparatively negligible on the subatomic level.
[edit] The electron
The electron charge to mass quotient, − e / me, is a quantity in experimental physics. It matters because the electron mass me is difficult to measure directly, and is instead derived from measurements of the fundamental charge e and e / me. It also has historical significance: Thomson's measurement of e / me convinced him that cathode rays were particles, which we know as electrons.
The 2006 CODATA recommended value is . CODATA refers to this as the electron charge to mass quotient, but ratio is still commonly used.
The "q/m" of an electron was successfully calculated by J. J. Thomson in 1897 and more successfully by Dunnington's Method which involves the angular momentum and deflection due to a perpendicular magnetic field.
There are two other common ways of measuring the charge to mass ratio of an electron, apart from J.J Thompson and the Dunnington Method.
1. The Magnetron Method- Using a GRD7 Valve (Ferranti valve), electrons are expelled from a hot tungsten wire filament towards an anode. The electron is then deflected using a solenoid. From the current in the solenoid and the current in the Ferranti Valve, e/m can be calculated
2. Fine Beam Tube Method- Electrons are accelerated from a cathode to a cap shaped anode. The electron is then expelled into a helium filled ray tube, producing a luminous circle. From the radius of this circle, e/m is calculated.
[edit] Zeeman Effect
The charge to mass ratio of an electron may also be measured with the Zeeman effect, which gives rise to energy splittings in the presence of a magnetic field B:
Here mj (final and initial) are quantum values ranging in integer steps from -j to j, with j as the eigenvalue of the operator . ( is the spin operator with eigenvalue s and the angular momentum operator with eigenvalue l.) gJ is the Landé-g factor, calculated as
The shift in energy is also given in terms of frequency ν and wavelength λ as
Measurements of the Zeeman effect commonly involve the use of a Fabry-Perot interferometer, with light from a source (placed in a magnetic field) and then passed between two mirrors of the interferometer. If δD is the change in mirror separation required to bring the mth order ring of wavelength λ + Δλ into coindicidence with that of wavelength λ and ΔD brings the (m + 1)th ring of wavelength λ into coindicence with the mth order ring, then
It follows then that
Rearranging, it is possible to solve for the charge-to-mass ratio of an electron as
[edit] See also
- Mass
- Charge
- Atomic mass unit
- Mass spectrometry
- Mass spectrum
- ISO 31-0 international standard on quantities and units
[edit] Further reading
- Books
- Electron and Ion Optics by Miklos Szilagyi, Plenum Press, ISBN 0-306-42717-6.
- Introduction into optics of charged particles by J. Grosser, Teubner, ISBN 3-519-03050-0.
- Applied charged particle optics, edited by A. Septier, Academic Press, ISBN 0-12-014574-X.
- Web sites
- BIPM SI brochure
- IUPAC green book on Quantities, Units and Symbols in Physical Chemistry
- Chapter 12: Mass Spectrometry in the IUPAC orange book
[edit] References
- NIST on units and manuscript check list
- Physics Today's instructions on quantities and units
- International Vocabulary of Basic Terms in Metrology (Second edition 1993: ISBN 92-67-01075-1); a guide with contributions of the following organizations: IUPAP, IUPAC, ISO, OIML, IEC, IFCC.
- IUPAP Red Book SUNAMCO 87-1 "Symbols, Units, Nomenclature and Fundamental Constants in Physics" (does not have an online version).
- Symbols Units and Nomenclature in Physics IUPAP-25 IUPAP-25, E.R. Cohen & P. Giacomo, Physics 146A (1987) 1-68.
- AIP style manual