In summer, temperatures on parts of the London Underground can become very uncomfortable due to its deep and poorly ventilated tube tunnels: temperatures as high as 47°C (116 °F) were reported in the 2006 European heat wave.[1] Posters may be observed on the Underground network advising that passengers carry a bottle of water to help keep cool.[2]
Contents |
[edit] Source
The heat in the tunnels is generated by the trains (motors and braking systems etc.), station equipment and body heat from the passengers. It is calculated that tube passengers account for about 56 gigawatt-hours of heat energy emitted on an average year.[3] Temperatures underground appear to be increasing gradually. This might be caused by the warming of the soil around the tunnels. Conventional brakes on trains rely on friction to slow the train down. This friction transforms the train's kinetic energy into heat. More modern trains feature regenerative braking systems that can feed the energy from braking back into the power supply. This means that the energy derived from braking is used somewhere else to power a train. This way energy is "re-used" and the amount of heat generated by braking is minimized. Another advantage is minimizing the amount of brake dust that is produced by the trains. This dust collects inside the tunnel system and is potentially hazardous to human health when inhaled.
[edit] Piston effect
Trains moving through the tight deep-level tunnels push air forward through the tunnels. This is called the piston effect. This effect can produce a strong wind blowing though the tunnels and stations but so far it has proven difficult to use this air movement to expel warm air and bring in cooler air.
[edit] Stations
Heat pumps were trialled in 1938 and have been proposed again recently to overcome this problem. Following a successful demonstration in 2001 funds were given to the School of Engineering at London's London South Bank University to develop a prototype; work began in April 2002. A prize of £100,000 was offered by the Mayor of London during the hot summer of 2003 for a solution to the problem, but the competition ended in 2005 without a winner.[3]
A year-long trial of a groundwater cooling system began in June 2006 at Victoria station. If successful the trial will be extended to 30 other deep-level stations.[4] For this trial Metronet installed London South Bank University's system comprising of 3 fan coil units which use water that has seeped into the tunnels and is pumped from the tunnels to absorb the heat after which it is discharged in the sewer system. The scheme was one of the winners in the Carbon Trust's 2007 Innovation Awards.[5]
[edit] Tube trains
Conventional air conditioning has been ruled out on the deep lines because of the lack of space for equipment on trains and the problems of dispersing the waste heat these would generate. Different systems have been proposed to cool Underground trains, most notably the use of massive blocks of ice inside the train. The blocks would be kept in refrigeration units, preventing them from melting completely.
[edit] Subsurface trains
In 2009, new S-stock trains will be delivered to replace the current A, C and D stock trains on the subsurface Lines (Metropolitan, Circle, Hammersmith & City, and District). These will have standard air-conditioning, as the subsurface tunnels are large enough to displace the exhausted hot-air.[6]
[edit] See also
[edit] References
- ^ Baking hot at Baker Street. BBC News.
- ^ Carry a bottle of water TfL poster.
- ^ a b Why does the Tube get so hot. The Londoner.
- ^ Water pump plan to cool the Tube. BBC News.
- ^ Carbon Trust announces finalists for 2007 Innovation Awards.
- ^ Subsurface network (SSL) upgrade. alwaystouchout.com.
[edit] External links
- The Underground Cooling Website
- Sustainable Cooling Schemes For The London Underground Railway Network
- Notes from Cooling the Tube Lecture 11 March 2008 - Kevin Payne Director of the Transport for London's 'Cooling the Tube' Program