JEA Northside Generating Station (Jacksonville)
From Wikipedia, the free encyclopedia
JEA Northside Generating Station in Jacksonville, Florida is a major power plant, one of the three power plants owned and operated by Jacksonville Electric Authority (JEA). It produces electricity by burning coal and petroleum coke at Units 1 and 2, the largest circulating fluidized-bed combustors, or CFBs, in the world. These combustors, completed in 2002, produce nearly 300 megawatts each, enough to light more than 250000 households.[1] In addition, a much older Unit 3 produces 518 megawatts of electricity by burning oil and/or natural gas.[2]
Contents |
[edit] Location
The Northside Generating Station is located at Coordinates: , to the north-east of the intersection of Routes 9A and 105 in the city of Jacksonville, Florida. It is 13.7 km (8.5 miles) from the Atlantic Ocean coastline, on the north bank of a back channel of the St. Johns River, which is being used as a waterway for fuel delivery as well as a source of cooling water. The Northside Generating Station also borders Timucuan Ecological and Historic Preserve that consists of North Florida wetlands and contains historic sites of Timucua peoples.
[edit] History
The Northside Generating Station began producing electricity for Jacksonville in 1966 with oil as its only fuel, when former Unit 1, rated at 275 megawatts, was installed. In 1972 a similar Unit 2 was launched, but had to be shut down in 1983 due to major boiler problems.[2] A 1977 plant expansion added a 518 megawatt Unit 3, which is still in operation today. This expansion enabled the use of oil and natural gas fuels. In 1996, JEA committed to reduce certain pollutants from the Northside Station by at least 10 percent when it upgraded Unit 2 (non-functional at the time) and Unit 1 by introducing the new clean coal technology.[1] This most recent upgrade fas funded by JEA (234 million USD) and the U.S. Department of Energy (75 million USD).[2] Initial synchronization was achieved for Unit 2 on February 19, 2002, and for Unit 1 on May 29, 2002.[2] As a result, the facility generates significantly more power now.
[edit] CFB Technology
CFB technology is an advanced method for burning coal and other fuels efficiently while removing air emissions inside the sophisticated combustor system. CFB technology provides flexibility in utility operations because a wide variety of solid fuels can be used, including high-sulfur, high-ash coal and petroleum coke.[3]
In a CFB combustor, coal or other fuels, air, and crushed limestone or other sorbents are injected into the lower portion of the combustor for initial burning of the fuel. The combustion actually occurs in a bed of fuel, sorbent, and ash particles that are fluidized by air nozzles in the bottom of the combustor. The air expands the bed, creates turbulence for enhanced mixing, and provides most of the oxygen necessary for combustion of the fuel. As the fuel particles decrease in size through combustion and breakage, they are transported higher in the combustor where additional air is injected. As the particles continue to decrease in size, unreacted fuel, ash, and fine limestone particles are swept out of the combustor, collected in a particle separator (also called a cyclone), and recycled to the lower portion of the combustor. This is the "circulating" nature of the combustor. Drains in the bottom of the combustor remove a fraction of the bed composed primarily of ash while new fuel and sorbent are added. The combustion ash is suitable for beneficial uses such as road construction material, agricultural fertilizer, and reclaiming surface mining areas.[3]
The limestone captures up to 98% of the sulfur impurities released from the fuel (DOE 1996). When heated in the CFB combustor, the limestone, consisting primarily of calcium carbonate (CaCO3), converts to calcium oxide (CaO) and CO2 . The CaO reacts with the SO2 from the burning fuel to form calcium sulfate (CaSO4), an inert material that is removed with the combustion ash. The combustion efficiency of the CFB combustor allows the fuel to be burned at a relatively low temperature of about 1650 F, thus reducing NOx formation by approximately 60% compared with conventional coal-fired technologies (DOE 1996). Greater than 99% of particulate emissions in the flue gas are removed downstream of the combustor by either an electrostatic precipitator or a fabric filter (baghouse).[3]
The heated combustor converts water in tubes lining the combustor's walls to high pressure steam. The steam is then superheated in tube bundles placed in the solids circulating stream and the flue gas stream. The superheated steam drives a steam turbine-generator to produce electricity in a conventional steam cycle.
[edit] Fuel supply
The plant uses a continuous ship unloader, the only one of its type in the continental U.S., that moves solid fuel from the barge onto the fuel conveyor system which transports it to the two largest fuel storage domes in North America.[1] Pet coke and coal travel from the ship to the domes in about twenty minutes, entirely inside a sealed system to prevent dust particles from escaping into the surrounding environment.
[edit] Water use
Water is obtained from the back channel of the St. Johns River to cool the Northside Generating Station condensers and it is returned to the back channel. An elevated intake flume delivers the water from the back channel to the station condensers. This cooling water does not mix with other liquid process streams while in contact with the condensers. Because Unit 2 has been out of service since 1983, the actual demand for cooling water by Northside Generating Station at full load since that time has been approximately 620 million gallons per day (Mgd), or 430700 gallons per minute (gpm), to operate Units 1 and 3. Operation of the entire 3-unit plant occurred only from about 1978 until 1980. During that time, the demand for cooling water was approximately 827 Mgd (574000 gpm): 24.5% for Unit 1, 24.5% for Unit 2, and 51% for Unit 3. This amount of surface water supplied to the station was approximately 10% of the average flow passing through the back channel of the St. Johns River.[4]
Before passing through the condensers, noncontact cooling water at Northside Generating Station is treated intermittently with a biocide to prevent biological growth on the heat exchanger tubes. Sodium hypochlorite (NaOCl) and occasionally sodium bromide (NaBr) are used. Treatment occurs no more than 2 hours per day per operating unit. The St. Johns River Power Park taps into the discharge side of the Northside Generating Station condensers to obtain cooling tower makeup. The average surface water flow supplied to the Power Park heat rejection system is 50 Mgd (34400 gpm). Approximately 25% of this surface water evaporates into the atmosphere from the cooling towers. Cooling tower blowdown is routed back into Northside Generating Station's discharge collector basin. The daily average temperature of the cooling tower blowdown is limited to 96 F.[4]
[edit] Emissions
Preliminary Emission Tests were conducted on Units 1 and 2 over the summer of 2002. Testing was conducted on both units burning coal and petroleum coke. Results are summarized in the table below. Emissions results from both units met all emission requirements for particulate, SO2, acid gases and heavy metals.[5]
Pollutant | Units | Emission Standard | Coal-fired | Petroleum Coke-fired |
---|---|---|---|---|
SO2 | lb/MMBTU | ≤ 0.15 | 0.0−0.04 | 0.03−0.13 |
NOx | lb/MMBTU | ≤ 0.09 | 0.04−0.06 | 0.02 |
Solid particulate | lb/MMBTU | ≤ 0.011 | 0.004 | 0.007 |
PM10 | lb/MMBTU | ≤ 0.011 | 0.006 | 0.004 |
SO3 | lb/hour | ≤ 1.1 | 0.43 | 0.0 |
Fluoride | lb/MMBTU | ≤ 1.57×10-4 | 1.06×10-4 | 0.95×10-4 |
Lead | lb/MMBTU | ≤ 2.6×10-5 | 0.56×10-5 | 0.59×10-5 |
Mercury | lb/MMBTU | ≤ 1.05×10-5 | 0.095×10-5 | 0.028×10-5 |
[edit] Conflicts and controversies
Soot coming from the JEA Northside Generating Station has prompted Distribution and Auto Services Inc. to threaten leaving Jacksonville area if the problem persists. Vehicle processing companies such as Auto Services Inc. prepare automobiles for dealers by cleaning, inspecting, customizing, and fixing defects. In 2001, such companies at Jacksonville processed 579924 vehicles. Auto Services Inc. had to wash 50000 cars to remove soot, the letter from the company's attorney said in 2002. The soot did not caused any damage to the vehicles, but a fallout occurring during a drizzle or when dew forms on vehicles could release acid that mars plastic equipment, the letter said. The JEA paid $82000 to the vehicle-processing company to cover the cost of washing automobiles during the summer of 2002, according to JEA spokesman.[6]
[edit] References
- ^ a b c http://www.nsrp.org/lean/lean_forum06/Tour_Description_JEA_Northside_Power_Station.pdf
- ^ a b c d The JEA Large-Scale CFB Combustion Demonstration Project, Clean Coal Technology, Topical Report Number 22, The U.S.Department of Energy and JEA (March, 2003)
- ^ a b c DOE/EIS-0289, Final Environmental Impact Statement for the JEA Circulating Fluidized Bed Combustor Project (June 1, 2000)
- ^ a b DOE/EIS-0289, Final Environmental Impact Statement for the JEA Circulating Fluidized Bed Combustor Project (June 1, 2000)
- ^ a b Goodrich, William; Sandell, Michael; Petti, Vincent; Rettura, Louis (2003). "Summary of air emissions from the first year operation of JEA's Northside Generating Station". Multi-Pollutant Emission Controls and Strategies, ICAC Forum. Retrieved on 2006-12-20.
- ^ Port tenant threatens pullout over soot 11/05/02