Fire monitor
From Wikipedia, the free encyclopedia
- "Deck gun" can also mean a type of artillery gun fitted to submarines.
- Distinguish from water monitor, which is a type of big lizard.
|
A fire monitor, deluge gun, or master stream, or deck gun is an aimable controllable high-capacity water jet used for manual firefighting or automatic fire protection systems. Fire monitors are often designed to accommodate foam which has been injected in the upstream piping. Fire monitors are often fitted to fire boats and on top of large firetrucks for use in manual fire fighting efforts. Fire monitors are also used in fixed fire protection systems to protect high hazards, such as aviation hangars and helicopter landing pads. Most manual fire monitors are able to be directed by a single firefighter, compared to a standard fire hose which normally requires several men. Fire Monitors can also be automatically positioned for fixed systems. They can pump up to, and sometimes over, 2000 gallons per minute (126 litres per second).
Manual fire monitors can be directed by one firefighter, compared to a standard fire hose which normally needs several people to operate.
Deluge guns are also available in portable designs so a firefighter can set up the gun to apply water to a blaze then leave it in place so the firefighter is free for other tasks. Facilities with highly flammable material such as oil refineries may have permanently installed deluge guns for use in the event of a fire.
A master stream is a fire service term for a water stream of 350 gallons per minute (1,320 lpm) or greater. It is delivered by master stream devices such as deck guns, deluge guns, and fire monitors. Master streams are often found at the end of aerial ladders, tele-squirt nozzles, or monitor nozzles. The high amount of required pressure makes them unsuitable for handline use.
A deck gun can be found fitted to fireboats and fire trucks for use in manual fire fighting efforts. It can be aimed and operated by one firefighter and is used to deliver water or foam from outside the immediate area of fire.
[edit] Risks
A master stream brings with it many risks when used in an urban setting. A master stream should never be fired into a building with people inside, as the force could knock down a supporting wall in a structure and crush victims. Also the steam expanding from the high volume of water delivered could cause a blowout or displace oxygen from an enclosed area, creating a risk of asphyxiation.
[edit] See also
[edit] Sources
- Hall, Richard; Adams, Barbara, Eds. (1998). Essentials of Fire Fighting, 4th, Stillwater, OK: Fire Protection Publication. ISBN 0-87939-149-9.
- US Patent for improved mobile fire apparatus
- Robert Allen Ltd. Press Release
- ABS Rules for Steel Vessels 2007 5C.9.11/3 Specific Vessel Types- Chemical Carriers, Fire Protection and Fire Extinction