Contact angle

From Wikipedia, the free encyclopedia

Image from a video contact angle device. Water drop on glass.
Image from a video contact angle device. Water drop on glass.

The contact angle is the angle at which a liquid/vapor interface meets the solid surface. The contact angle is specific for any given system and is determined by the interactions across the three interfaces. Most often the concept is illustrated with a small liquid droplet resting on a flat horizontal solid surface. The shape of the droplet is determined by the Young-Laplace equation. The contact angle plays the role of a boundary condition. Contact angle is measured using a contact angle goniometer. The contact angle is not limited to a liquid/vapour interface; it is equally applicable to the interface of two liquids or two vapours. Companies such as Kyowa have developed equipment to measure microscopic contact angle and dynamic contact angle.


Contents

[edit] Typical contact angles

Consider a liquid drop on a solid surface. If the liquid is very strongly attracted to the solid surface (for example water on a strongly hydrophilic solid) the droplet will completely spread out on the solid surface and the contact angle will be close to 0°. Less strongly hydrophilic solids will have a contact angle up to 90°. On many highly hydrophilic surfaces, water droplets will exhibit contact angles of 0° to 30°. If the solid surface is hydrophobic, the contact angle will be larger than 90° . On highly hydrophobic surfaces the surfaces have water contact angles as high as 150° or even nearly 180°. On these surfaces, water droplets simply rest on the surface, without actually wetting to any significant extent. These surfaces are termed superhydrophobic and can be obtained on fluorinated surfaces (Teflon-like coatings) that have been appropriately micropatterned. This is called the Lotus effect, as these new surfaces are based on lotus plants' surface (which has little protuberances) and would be superhydrophobic even to honey. The contact angle thus directly provides information on the interaction energy between the surface and the liquid.

Sometimes the contact angle is measured through the gas instead of through the liquid, which reverses 0 and 180 in the above explanation.

[edit] Thermodynamics

A contact angle of a liquid sample
A contact angle of a liquid sample

The theoretical description of contact arises from the consideration of a thermodynamic equilibrium between the three phases: the liquid phase of the droplet (L), the solid phase of the substrate (S), and the gas/vapor phase of the ambient (V) (which will be a mixture of ambient atmosphere and an equilibrium concentration of the liquid vapor). The V phase could also be another (immiscible) liquid phase. At equilibrium, the chemical potential in the three phases should be equal. It is convenient to frame the discussion in terms of the interfacial energies. We denote the solid-vapor interfacial energy (see surface energy) as γSV, the solid-liquid interfacial energy as γSL and the liquid-vapor energy (i.e. the surface tension) as simply γ, we can write an equation that must be satisfied in equilibrium (known as the Young Equation):

0=\gamma_\mathrm{SV} - \gamma_\mathrm{SL} - \gamma \cos \theta_\mathrm{0} \,

where θ0 is the equilibrium contact angle. The Young equation assumes a perfectly flat surface, and in many cases surface roughness and impurities cause a deviation in the equilibrium contact angle from the contact angle predicted by Young's equation. Even in a perfectly smooth surface a drop will assume a wide spectrum of contact angles between the highest (advancing) contact angle, θA, and the lowest (receding) contact angle, θR. The equilibrium contact angle (θ0) can be calculated from θA and θR as was shown by Tadmor [1]:


\theta_\mathrm{0}=\arccos{\frac{r_\mathrm{A}\cos{\theta_\mathrm{A}}+r_\mathrm{R}\cos{\theta_\mathrm{R}}}{r_\mathrm{A}+r_\mathrm{R}}}

Where,


r_\mathrm{A}=\sqrt[3]{\frac{\sin^3{\theta_\mathrm{A}}}{2-3\cos{\theta_\mathrm{A}}+\cos^3{\theta_\mathrm{A}}}}

and,


r_\mathrm{R}=\sqrt[3]{\frac{\sin^3{\theta_\mathrm{R}}}{2-3\cos{\theta_\mathrm{R}}+\cos^3{\theta_\mathrm{R}}}}


The contact angle can also be used to determine an interfacial energy (if other interfacial energies are known). This equation can be rewritten as the Young-Dupré equation:

\gamma (1 + \cos \theta )= \Delta W_\mathrm{SLV} \,

where ΔWSLV is the adhesion energy per unit area of the solid and liquid surfaces when in the medium V.


[edit] Measuring methods

A modern contact angle goniometer.
A modern contact angle goniometer.
The static sessile drop method 
The sessile drop method is measured by a contact angle goniometer using an optical subsystem to capture the profile of a pure liquid on a solid substrate. The angle formed between the liquid/solid interface and the liquid/vapor interface is the contact angle. Older systems used a microscope optical system with a back light. Current-generation systems employ high resolutions cameras and software to capture and analyze the contact angle.
The dynamic sessile drop method 
The dynamic sessile drop is similar to the static sessile drop but requires the drop to be modified. A common type of dynamic sessile drop study determines the largest contact angle possible without increasing its solid/liquid interfacial area by adding volume dynamically. This maximum angle is the advancing angle. Volume is removed to produce the smallest possible angle, the receding angle. The difference between the advancing and receding angle is the contact angle hysteresis.
Dynamic Wilhelmy method 
A method for calculating average advancing and receding contact angles on solids of uniform geometry. Both sides of the solid must have the same properties. Wetting force on the solid is measured as the solid is immersed in or withdrawn from a liquid of known surface tension.
Single-fiber Wilhelmy method 
Dynamic Wilhelmy method applied to single fibers to measure advancing and receding contact angles.
Powder contact angle method 
Enables measurement of average contact angle and sorption speed for powders and other porous materials. Change of weight as a function of time is measured.

[edit] See also

[edit] References

  1. ^ Rafael Tadmor. "Line energy and the relation between advancing, receding and Young contact angles", Langmuir, 20, 7659-7664, (2004). 

[edit] External links