Animal By-Products Regulations

From Wikipedia, the free encyclopedia

The Animal By-Products Regulations (No 1774/2002) (SI 1482/2003) allows for the treatment of some animal by-products in composting and biogas plants (anaerobic digesters). The following article describes procedures required to allow solid outputs (compost, digestate) from composting plants and anaerobic digesters onto land in the United Kingdom.

Contents

[edit] Categories of Animal By-Products

  • Category 1: Very high risk
  • Category 2: High risk
  • Category 3: Low risk

[edit] Category 1

Must all be destroyed, not for use in composting or biogas plants

[edit] Category 2

Can be used in composting and biogas plants after rendering (133C, 3 bar pressure) Manure and gut contents only can be used without pretreatment

[edit] Category 3

  • Catering waste from households, restaurants
  • Former food
  • Much slaughter house waste e.g. waste blood & feathers

Can be used in composting and biogas plants without pretreatment

[edit] Treatment Standards

[edit] Composting

Closed reactor

  • Maximum particle size 40cm, minimum temperature 60C, minimum time at that temperature 2 days
  • Maximum Particle size 6cm, minimum temperature 70C, minimum time at that temperature 1 hour

Housed windrow

  • Particle size 40cm, minimum temperature 60C, minimum time at that temperature 8 days

[edit] Biogas plants

  • Maximum particle size 5cm, minimum temperature 57C, minimum time at that temperature 5 hours
  • Maximum particle size 12cm, minimum temperature 70C, minimum time at that temperature 1 hour

[1]

[edit] References

  1. ^ ABPR 1

[edit] See also