A2W reactor
From Wikipedia, the free encyclopedia
The A2W reactor is a naval reactor used by the United States Navy to provide electricity generation and propulsion on warships. The A2W designation stands for:
- A = Aircraft carrier platform
- 2 = Second generation core designed by the contractor
- W = Westinghouse was the contracted designer
This nuclear reactor was used in the world's first nuclear-powered aircraft carrier, the USS Enterprise (CVN-65). The four propulsion plants on Enterprise each contain two reactors, numbered 1A-1B, 4A - 4B, 2A - 2B, and 3A - 3B (numbered as they are located from fore to aft). Each propulsion plant is capable of operating on one reactor plant through most of the power range required to propel the ship at speeds in excess of 33 knots (61 km/h) (with a possible maximum speed up to approximately 35 knots; higher speeds such as the 40-50 knots sometimes rumored would rapidly become impossible due to hydrodynamic drag even if the reactors were capable of delivering enough power). Both reactors would be on-line to simultaneously provide maximum ship speed and plane launching capability.
[edit] Design and operation
The reactors are pressurized water reactors fueled by highly-enriched (upwards of 93%) U-235[citation needed]. Light water is used as both neutron-moderator and reactor coolant. Hafnium Control rods are used to control the operation of the reactor. Extracting the rods to a calculated height allows the reactor to reach "criticality" - the point at which the nuclear fission reactions reach a self-sustaining level. Thereafter, steam flow (from the steam generators) regulates reactor power as explained below. The control rods are "shimmed" in or out to regulate average coolant temperature or lowered to the bottom of the reactor vessel to shut the reactor down (either done in a slow controlled manner or dropped rapidly during what is referred to as a SCRAM to immediately shut the reactor down.
Much of the reactor power control during steady state operation comes as a result of the coolant water's negative temperature coefficient. The "power" of the reactor is determined by the number of fission events that takes place in the fuel at any given moment. As the water heats up, it expands and becomes less dense which provides fewer molecules per volume to moderate the neutrons, hence fewer neutrons are slowed to the required thermal energies to sustain thermal fission. Conversely, when the coolant water temperature decreases, its density increases and a greater number of neutrons reach the required thermal energy, increasing the number of fissions per unit of time, creating more heat. This has the effect of allowing "steam demand" to control reactor power, requiring little intervention by the Reactor Operator for changes in the power demanded by the ship's operations.
The hot water from the reactors is sent, via large pipes, into heat exchangers called steam generators. There the heat from the reactor coolant water is transferred, through tube walls, to water being fed into the steam generators from a separate feed system. In the A1W and A2W systems, the pressurized water reactor coolant is kept between 525 and 545 °F (274 and 285 °C). In the steam generators, the water from the feed system is converted to steam at 535 °F (279 °C) and a pressure of about 600 lb/in² (4 MPa). Once the reactor coolant water has given off its heat in the steam generators, it is returned, via large electric pumps (four per reactor), to the reactors to repeat the cycle.
Saturated steam at 600 lb/in² (4 MPa) is channeled from each steam generator to a common header, where the steam is then sent to the main engine, electrical generators, aircraft catapult system, and various auxiliaries. The main propulsion turbines are double-ended, in which the steam enters at the center and divides into two streams as it enters the actual turbine wheels, expanding and giving up its energy as it does so, causing the turbine to spin at high speed. The main shaft enters a reduction gear in which the high rotational velocity of the turbine shaft is stepped down to a usable turn rate for propelling the ship. The expended steam from the main engine and other auxiliaries enters condensers to be cooled into water and recycled to the feed system.
|