Crowbar (circuit)

From Wikipedia, the free encyclopedia

A crowbar or crowbar circuit is an electrical circuit used to prevent an overvoltage condition of a power supply unit from damaging the circuits attached to the power supply. It operates by putting a short circuit across the voltage source, much as if one dropped a tool of the same name across the output terminals of the power supply. Crowbar circuits are frequently implemented using a thyristor (also called an SCR) or a trisil or thyratron as the shorting device. Once triggered, they depend on the current-limiting circuitry of the power supply or, if that fails, the blowing of the line fuse or circuit breaker.

A crowbar circuit is distinct from a clamp in that, once triggered, it pulls the voltage below the trigger level, usually close to ground. A clamp prevents the voltage from exceeding a preset level. Thus, a crowbar will not automatically return to normal operation when the overvoltage condition is removed; power must be removed entirely to stop its conduction.

The advantage of a crowbar over a clamp is that the low holding voltage of the crowbar lets it carry higher fault current without dissipating much power which could cause overheating. Also, a crowbar is more likely than a clamp to deactivate a device (by blowing a fuse, or throwing breakers), bringing attention to the faulty equipment.

The term is also used as a verb to describe the act of short-circuiting the output of a power supply.

In other languages